G. General
Function
After deactivating the Speed_Enable and after the GP3 time
has elapsed, if the motor has not stopped, it cancels the
torque automatically and issues error E.004. If the motor
stops within the GP3 time, it also cancels the torque but does
not issue an error. To make this time infinite (never generating
error E.004), set this parameter to “0”.
Valid values
1 ... 9999 ms, 0 (infinite).
Default value
500 ms.
Function
This parameter represents the version of the parameter table
that has been loaded at the drive.
Function
After the motor has stopped because the Speed Enable
function has been disabled, the cancellation of the Drive
Enable (that implies PWM-OFF) is delayed by a time period
indicated by GP9. It is useful on axes not compensated with
a holding brake. To make this time period infinite, set it to 0
and to remove it, set it to 1.
Valid values
1 ... 9999 ms, 0 (infinite).
Default value
50 ms.
Function
When having a SinCos or SinCoder encoder it enables
reading MP1 directly from the sensor and consequently
loading certain drive parameter automatically.
If GP15 = 0, it does not check the format of MP1.
Valid values
0/1 Disabled/enabled (by default).
Function
It enables or disables the option to feed ACSD-xxL (220 V
AC) with single-phase power voltage without activating the
error code for missing phase. Keep in mind that on 20 A and
30 A drives, the software will limit the current internally to 10
A.
Valid values
0/1 Disabled (by default)/enabled.
GP3
BASIC, RW
S33470
StoppingTimeout
GP5
BASIC, RO
S33468
ParameterVersion
GP9
BASIC, RW
S00207
DriveOffDelayTime
GP15 FAGOR, RW
S33494
AutomaticInitialization
GP16 BASIC, RW
S33495
MonoPhaseSelector
NOTE.
Not being used on ACSD-xxH (400 V AC) units.
The bus voltage will not be reached when feeding these
units with single-phase voltage.
Summary of Contents for ACSD series
Page 1: ...FAGOR AUTOMATION S COOP Brushless AC Servo Drives ACSD series Ref 1609 Original instructions ...
Page 6: ...ACSD 6 80 Digital Brushless AC Servo Drive system Ref 1609 This page intentionally left blank ...
Page 78: ...ACSD 78 80 Digital Brushless AC Servo Drive system Ref 1609 User notes ...
Page 79: ...Digital Brushless AC Servo Drive system Ref 1609 ACSD 79 80 User notes ...