![Fagor ACSD series Original Instructions Manual Download Page 65](http://html.mh-extra.com/html/fagor/acsd-series/acsd-series_original-instructions-manual_538347065.webp)
Digital Brushless
AC S
ervo
D
rive system - Ref.1609
ACSD-65/80
SP2: 0.1... 999.9 ms.
Default value
Depends on the motor-drive combination.
Function
Maximum velocity limit for SV7 (VelocityCommandFinal).
Valid values
0 ... 110 % of the motor rated speed in rpm.
Default value
1 000 rpm.
Function
Determines the value of the velocity window around zero
that will be considered to be zero speed.
Valid values
0 ... motor rated speed in rpm.
Default value
20 rpm.
Function
This parameter is used to change the sign of the velocity
command in specific applications. It cannot be used to solve
a positive feedback problem (axis runaway).
Valid values
0/1 Not inverted/inverted.
Default value
0 Not inverted.
SP10
BASIC, RW
S00091
VelocityLimit
SP42
USER, RW
S00124
StandStillWindow
SP43
BASIC, RW
S00043
VelocityPolarityParameters
Summary of Contents for ACSD series
Page 1: ...FAGOR AUTOMATION S COOP Brushless AC Servo Drives ACSD series Ref 1609 Original instructions ...
Page 6: ...ACSD 6 80 Digital Brushless AC Servo Drive system Ref 1609 This page intentionally left blank ...
Page 78: ...ACSD 78 80 Digital Brushless AC Servo Drive system Ref 1609 User notes ...
Page 79: ...Digital Brushless AC Servo Drive system Ref 1609 ACSD 79 80 User notes ...