If anytime during the sequence, the Drive Enable is
interrupted, the motor will turn by inertia.
SP65=0 cancels this limiting effect.
Valid values
0.0 (by default), ..., 400.0 rpm/ms.
Function
Determines the value of the deceleration ramp applied to
the velocity command. Setting it with a zero value means
that no ramps will be applied.
Valid values
0.0 (by default), ..., 400.0 rpm/ms.
Function
Velocity command after the SP45 selector.
Valid values
- 6 000.0000 ... 6 000.0000 rpm.
Function
Velocity feedback.
Valid values
- 6 000.0000 ... 6 000.0000 rpm.
Function
Velocity command after applying limits, ramps, etc.
Valid values
- 6 000.0000 ... 6 000.0000 rpm.
Function
Final velocity command applied to the loop.
Valid values
- 6 000.0000 ... 6 000.0000 rpm.
SP66
BASIC, RW
S34386
VelocityDecelerationTime
SV1
BASIC, RW
S00036
VelocityCommand
SV2
BASIC, RO
S00040
VelocityFeedback
SV6
BASIC, RO
S34390
VelocityCommandAfterFilters
SV7
BASIC, RO
S34380
VelocityCommandFinal
Motor free
Power Off
Drive
Enable
Power Off
Speed
Enable
Motor
Speed
Drive
Enable
Speed
Enable
Motor
Speed
Summary of Contents for ACSD series
Page 1: ...FAGOR AUTOMATION S COOP Brushless AC Servo Drives ACSD series Ref 1609 Original instructions ...
Page 6: ...ACSD 6 80 Digital Brushless AC Servo Drive system Ref 1609 This page intentionally left blank ...
Page 78: ...ACSD 78 80 Digital Brushless AC Servo Drive system Ref 1609 User notes ...
Page 79: ...Digital Brushless AC Servo Drive system Ref 1609 ACSD 79 80 User notes ...