Digital Brushless
AC S
ervo
D
rive system - Ref.1609
ACSD-53/80
Function
Display the rms current circulating through the motor.
Valid values
- 50.00 ... 50.00 Arms (rms value).
Function
Value of the automatic compensation of the current feed-
back offset of phase V.
Valid values
- 2.000 ... 2.000 A (depends on the drive connected).
Function
Value of the automatic compensation of the current feed-
back offset of phase W.
Valid values
- 2.000 ... 2.000 A (depends on the drive connected).
D. Diagnosis
Function
Stores the last 5 errors that came up at the drive. It is a 5-
word register that stores the numbers of the last 5 errors
originated at the drive.
Valid values
All the numbers of the possible errors of the software version
loaded. Code 0 means no error.
Function
This variable contains a numerical data coded into 16 binary
bits and represents the system status as shown by the
attached table. Bits (from the most to the least significant).
CV3
USER, RO
S33079
CurrentFeedback
CV10 FAGOR, RO
S33073
Current1Offset
CV11 FAGOR, RO
S33074
Current2Offset
DV17 USER, RO
S33178
HistoricOfErrors
DV31 FAGOR, RO
S00135
DriverStatusWord
Bit Nr
Function
15, 14
Power & Torque Status
0,0 DoingInternalTest DRVSTS_INITIALIZATING
0,1 ReadyForPower DRVSTS_LBUS
1,0 PowerOn DRSTS_POWER_ON
1,1 TorqueOn DRSTS_TORQUE_ON
13
Error bit
_cos
_sin
CV1
CV2
AD
CV10
CV11
IV
IW
Current
reading
Summary of Contents for ACSD series
Page 1: ...FAGOR AUTOMATION S COOP Brushless AC Servo Drives ACSD series Ref 1609 Original instructions ...
Page 6: ...ACSD 6 80 Digital Brushless AC Servo Drive system Ref 1609 This page intentionally left blank ...
Page 78: ...ACSD 78 80 Digital Brushless AC Servo Drive system Ref 1609 User notes ...
Page 79: ...Digital Brushless AC Servo Drive system Ref 1609 ACSD 79 80 User notes ...