![Fagor ACSD series Original Instructions Manual Download Page 33](http://html.mh-extra.com/html/fagor/acsd-series/acsd-series_original-instructions-manual_538347033.webp)
Digital Brushless
AC S
ervo
D
rive system - Ref.1609
ACSD-33/80
INSTALLATION
General considerations
At the motor
Remove the anti-corrosion paint of the shaft before mounting them on to the machine.
The motor may be mounted as IM B5, IM V1 and IM V3.
Watch for the ambient conditions mentioned in the section on general characteristics and
also:
Start the drive up (or do a reset) with the rotary switch in the “0” position.
Mount it somewhere that is dry, clean and accessible for maintenance.
It must be easily cooled.
Avoid corrosive or flammable environments.
Guard the motor with a cover if it is exposed to splashes.
Use flexible coupling for direct transmission.
Avoid radial and axial loads on the motor shaft.
At the drive
The module must be installed in an electrical cabinet that is clean, dry, free of dust, oil
and other pollutants.
Never install it exposing it to flammable gases. Avoid excessive heat and humidity. The
ambient temperature must never exceed 45°C/113°F. Install the modules vertically,
avoid vibrations and respect the gaps to allow air flow. See figure
.
NOTE.
Remember that the degree of protection is IP 64.
MANDATORY.
Do not hit the shaft when installing transmission pulleys or
gears!
Use some tool that is supported in the threaded
hole on the shaft to insert the pulley or the gear.
NOTE.
Remember that the degree of protection is IP 20.
Summary of Contents for ACSD series
Page 1: ...FAGOR AUTOMATION S COOP Brushless AC Servo Drives ACSD series Ref 1609 Original instructions ...
Page 6: ...ACSD 6 80 Digital Brushless AC Servo Drive system Ref 1609 This page intentionally left blank ...
Page 78: ...ACSD 78 80 Digital Brushless AC Servo Drive system Ref 1609 User notes ...
Page 79: ...Digital Brushless AC Servo Drive system Ref 1609 ACSD 79 80 User notes ...