The table below shows the values recommended for the fuses shown in the previous
figure. They are slow general purpose fuses. If they are installed on the Mains input
lines, their maximum currents will depend on the value of the Mains voltage.
F. 19
Three-phase drive connection to mains.
F. 20
Connection of the single-phase drive (only ACSD-05L and ACSD-10L) to mains.
Model
Ipeak
Fuse
Model
Ipeak
Fuse
Units
A
A
Units
A
A
ACSD-05L
05
04
ACSD-04H
04
04
ACSD-10L
10
08
ACSD-08H
08
08
ACSD-20L
20
16
ACSD-16H
16
16
ACSD-30L
30
25
Note.
When installing several ACSD's with a single contactor -KM1, there is no need for external
fuses (in terms of protection) in the control board supply line. There is an internal fuse in series with
one of the input phases. External fuses or magneto-thermal switches may be installed with a differ-
ent purpose (handling). Consider an approximate current 1 A.
L1
L2
X3
220 or 380 V AC
R
S
T
N
380 V AC
CO
NTROL
PO
W
E
R
IN
PU
T
POW
E
R
IN
PUTS
R
S
T
N
High
floating
voltage
Autotransformer or
three -phase transformer
Autotransformer or
three -phase transformer
Warning.
Never make this connection because
there is a risk of destroying the module.
- KM1
power switch
fuses
3x2.5 mm²
L3
L1
L2
fuses
X3
CO
NTROL
PO
W
E
R
IN
PU
T
L1
L2
L1
L2
POW
E
R
I
N
PUT
S
- KM1
power switch
3x2.5 mm²
L3
THREE PHASE
220 or 380 V AC
220 or 380 V AC
220 or 380 V AC
380 V AC
Note.
When installing several ACSD's with a single contactor -KM1, there is no need for external
fuses (in terms of protection) in the control board supply line. There is an internal fuse in series with
one of the input phases. External fuses or magneto-thermal switches may be installed with a different
purpose (handling). Consider an approximate current 1 A.
L1
L2
X3
R
S
T
N
CO
N
T
ROL
POW
E
R
IN
PUT
PO
WER
I
N
P
U
TS
R
S
T
N
High
floating
voltage
Autotransformer or
three -phase transformer
Autotransformer or
three -phase transformer
Warning.
Never make this connection because
there is a risk of destroying the module.
fuses
2x2.5 mm²
L3
L1
L2
fuses
X3
CO
N
T
ROL
PO
WER
I
N
P
U
T
L1
L2
L1
L2
2 2 0 V A C
POW
E
R
IN
PU
TS
2x2.5 mm²
L3
Note.
Only in ACSD-05L and ACSD-10L models
SINGLE - PHASE
- KM1
power switch
- KM1
power switch
380 V AC
380 V AC
2 2 0 V A C
2 2 0 V A C
2 2 0 V A C
Summary of Contents for ACSD series
Page 1: ...FAGOR AUTOMATION S COOP Brushless AC Servo Drives ACSD series Ref 1609 Original instructions ...
Page 6: ...ACSD 6 80 Digital Brushless AC Servo Drive system Ref 1609 This page intentionally left blank ...
Page 78: ...ACSD 78 80 Digital Brushless AC Servo Drive system Ref 1609 User notes ...
Page 79: ...Digital Brushless AC Servo Drive system Ref 1609 ACSD 79 80 User notes ...