INSTRUCTION MANUAL DAAB AUTOMATIC CONTROL UNIT EP105
44
Revision 3
• Limit switch, L-channels
No.
Name
Range
Factory Setting Ref. page
L001
Choice of limit switch type for motor 1
0 - 3
0
0
Motor 1 disabled, no limit switch chosen
1
Encoder
2
Limit switch
3
Time
4
Hold-to-run without limit switches. NOTE! Only one half at a time can be run. C033 must be set to 5.
L002
Choice of limit switch type for motor 2
0 - 3
0
0
Motor 2 disabled, no limit switch chosen
1
Encoder
2
Limit switch
3
Time
4
Hold-to-run without limit switches. NOTE! Only one half at a time can be run. C033 must be set to 5.
Encoder
L110
1
Position of motor 1, viewed from the motor side
0 - 2
1
0
No location chosen, L111 shows 000
1
Left
2
Right
L111
1
Position angle readout motor 1
000-360 degrees
L112
1
Angle for open position, motor 1
145-330 degrees
260
L113
1
Limit for closed position, motor 1
015-200 degrees
90
L116
1
Angle for limited opening, motor 1.
0-200 degrees
45
L117
1
Angle for disconnection of safety edge, load
guard and photocell from the end of the closing
movement, motor 1 in combination with C436,
C341 and C448
0-30 degrees
0
L118
1
Angle for the disconnection of vehicle loops from
the end of the closing movement, motor 1 in
combination with d141 or d241.
0-45 degrees
0
L120
2
Position of motor 2, viewed from the motor side
0 - 2
2
0
No location chosen, L121 shows 000
1
Left
2
Right
L121
2
Position angle readout motor 2
000-360 degrees
L122
2
Angle for open position, motor 2
145-330 degrees
260
L123
2
Limit for closed position, motor 2
015-200 degrees
90
L126
2
Angle for limited opening, motor 2.
0-200 degrees
45
L127
2
Angle for disconnection of safety edge, load
guard and photocell from the end of the closing
movement, motor 2 in combination with C436,
C341 and C448
0-30 degrees
0
L128
2
Angle for the disconnection of vehicle loops from
the end of the closing movement, motor 2 in
combination with d141 or d241.
0-45 degrees
0
1
= Only displayed if L001 is set to 1 or 4.
2
= Only displayed if L002 is set to 1 or 4.