INSTRUCTION MANUAL DAAB AUTOMATIC CONTROL UNIT EP105
43
Revision 3
Service channels
No.
Name
Range
Factory Setting Ref. page
C900
Service channel, for service personnel only Random
number
000 - 999
C901
Service channel, for service personnel only.
00 - 99
00
00
No function selected
10
Channel values locked for editing.
80
Erasure of error code list in channel C903
C902
Service channel, for service personnel only,
checksum
0000-FFFF
C903
Error code list showing the most recent error
events.
¯¯¯¯
Start of the list, followed by the latest message when the minus button is
pressed.
E003-E976
Error messages, use + and - buttons to step up or down.
n021-n074
Message, use + and - buttons to step up or down.
_____
End of the list, followed by the oldest message when the plus button is
pressed.
C904
Message on display and in error code list.
0 – 1
1
0
Message is neither displayed nor stored in the error code list
1
Message is displayed and stored in the error code list
C999
Display mode
0 - 4
2
0
No restriction on channel display.
1
Shows only channels that differ from factory settings, use + and - to step up or down. The button on
the far left is used for rapid stepping between the channel groups, has no function in this position.
2
Displays only the channels needed for choosing voltage supply, setting of open and closed position
and motor protection.
3
Displays only the channels needed for setting of load guard, motor protection, gear ratio, limit switch
type and selection of application.
4
Displays channels for selecting application and add-on boards.