INSTRUCTION MANUAL DAAB AUTOMATIC CONTROL UNIT EP105
47
Revision 3
Programmable input 2
No.
Name
Range
Factory Setting Ref. page
P200
Programmable input 2
0 - 1
1
0
Disabled
1
Enabled
P260
Control function
0-5
2
0
Disabled
1
Open
2
Close
3
Stop
4
Open/close
5
Open/stop/close
S
P261 Type of control signal when activated
1 - 2
1
1
Pulse (hold-to-run mode not possible)
2
Signal for as long as the input is activated
P262
Half operation
1 - 3
3
1
Motor 1
2
Motor 2
3
Motors 1 and 2
P263
Limited opening
0 - 1
0
0
Disabled
1
Opening according to set time in channel L216/L226 or number of degrees in L116/L126 if encoder
is used.
P270
Motor lock
0 - 1
0
0
Disabled
1
The barrier cannot be operated without a signal at programmable input 2.
If the signal disappears ongoing movement stops.
P275
Opening via input after activation during set
time, input will not open the gate until it has been
activated for the set time.
0.0-9.9 seconds
0.0
P280
Park
0 - 2
0
0
Disabled
1
Automatic closing disabled after the input is activated, reset by another control signal
2
Automatic closing disabled by a constant signal.
P290
Interlock opening
0 - 1
0
0
Disabled
1
Opens the local door if P260 is set to open, and passes the signal on to the remote door
P296
Blocking disabled for local and remote doors. Works
only with a constant signal.
0 - 1
0
0
Disabled, function according to channel C614
1
Blocking disabled
P298
Automatic closing switched off for remote door.
Only works if there is a constant signal
0 - 1
0
0
Disabled, function according to channel C500
1
Automatic closing switched off