INSTRUCTION MANUAL DAAB AUTOMATIC CONTROL UNIT EP105
52
Revision 3
No.
Name
Range
Factory Setting Ref. page
P670
Motor lock
0 - 1
0
0
Disabled
1
The barrier cannot be operated without a signal at programmable input 6.
If the signal disappears ongoing movement stops.
P675
Opening via input after activation during set
time, input will not open the gate until it has been
activated for the set time.
0.0-9.9 seconds
0.0
P680
Park
0 - 2
0
0
Disabled
1
Automatic closing disabled after the input is activated, reset by another control signal
2
Automatic closing disabled by a constant signal.
P690
Interlock opening
0 - 1
0
0
Disabled
1
Opens the local door if P660 is set to open, and passes the signal on to the remote door
P696
Blocking disabled for local and remote doors. Works
only with a constant signal.
0 - 1
0
0
Disabled, function according to channel C614
1
Blocking disabled
P698
Automatic closing switched off for remote door.
Only works if there is a constant signal
0 - 1
0
0
Disabled, function according to channel C500
1