INSTRUCTION MANUAL DAAB AUTOMATIC CONTROL UNIT EP105
36
Revision 3
No.
Name
Range
Factory Setting Ref. page
S
C121 Selects function for safety edge SE.C2
0-2
2
0
SE.C2 disabled
1
Limits according to set value in C125
2
Fixed limits between 5 kΩ and 15 kΩ
S
C122 Reverse/stop with activated safety edge SE.C2
1 – 2
1
1
Reverse
2
Stop
S
C123 Control of external protection connected to SE.C2 0 - 1
1
0
No check
1
Test of protection connected to SE.C2 if C102 is enabled
C124
Reading impedance SE.C2
00.0-99.9 kΩ
S
C125
Setting impedance value for safety edge SE.C2
Set to 1 only at C121.
1.0-9.9 kΩ
8.2
S
C131 Selects function for SE.O1
0-2
0
0
SE.O1 disabled
1
Limits according to set value in C135
2
Fixed limits between 5 kΩ and 15 kΩ
S
C132 Reverse/stop with activated safety edge SEO1
1 – 2
1
1
Reverse
2
Stop
S
C133 Control of external protection connected to SE.O1 0 - 1
1
0
No check
1
Test of protection connected to SE.O1 if C102 is enabled
C134
Reading impedance SE.O1
00.0-99.9 kΩ
S
C135
Setting impedance value for safety edge SE.O1. Set
to 1 only at C131.
1.0-9.9 kΩ
8.2
S
C141 Selects function for SE.O2
0-2
0
0
SE.O2 disabled
1
Limits according to set value in C135
2
Fixed limits between 5 kΩ and 15 kΩ
S
C142 Reverse/stop with activated safety edge SE.02
Subordinate to channel C104
1 – 2
1
1
Reverse
2
Stop
S
C143 Control of external protection connected to SE.O2 0 - 1
1
0
No check
1
Test of protection connected to SE.O2 if C102 is enabled
C144
Reading impedance SE.O2
00.0-99.9 kΩ
S
C145
Setting impedance value for safety edge SE.O2. Set
to 1 only at C141.
1.0-9.9 kΩ
8.2