INSTRUCTION MANUAL DAAB AUTOMATIC CONTROL UNIT EP105
46
Revision 3
• Programmable inputs, P channels
Programmable input 1
No.
Name
Range
Factory Setting Ref. page
P100
Programmable input 1
0 - 1
1
0
Disabled
1
Enabled
P160
Control function
0 - 5
1
0
Disabled
1
Open
2
Close
3
Stop
4
Open/close
5
Open/stop/close
S
P161 Type of control signal when activated
1 - 2
1
1
Pulse (hold-to-run mode not possible)
2
Signal for as long as the input is activated
P162
Half operation
1 - 3
3
1
Motor 1
2
Motor 2
3
Motors 1 and 2
P163
Limited opening
0 - 1
0
0
Disabled
1
Opening according to set time in channel L216/L226 or number of degrees in L116/L126 if encoder
is used.
P170
Motor lock
0 - 1
0
0
Disabled
1
The barrier cannot be operated without a signal at programmable input 1.
If the signal disappears ongoing movement stops.
P175
Opening via input after activation during set time,
input will not open the gate until
it has been activated for the set time.
0.0-9.9 seconds
0.0
P180
Park
0 - 2
2
0
Disabled
1
Automatic closing disabled after the input is activated, reset by another control signal
2
Automatic closing disabled by a constant signal.
P190
Interlock opening
0 - 1
0
0
Disabled
1
Opens the local door if P160 is set to open, and passes the signal on to the remote door
P196
Blocking disabled for local and remote doors. Works
only with a constant signal.
0 - 1
0
0
Disabled, function according to channel C614
1
Blocking disabled
P198
Automatic closing switched off for remote door.
Only works if there is a constant signal
0 - 1
0
0
Disabled, function according to channel C500
1
Automatic closing switched off