General time channels.
No.
Name
Range
Factory Setting Ref. page
S
C436 Stop during run-on time or disengagement angle in
closing, subordinated to C448 and C449
0 - 3
3
0
No stop function activated
1
Stop with triggered load guard
2
Stop with activated safety edge
3
Stop with activated safety edge or with triggered load guard
S
C448 Reversing during run-on time or disengagement
angle with
safety edge
activated, L117, L127, L213,
L223
0 - 2
2
0
No reversing
1
Reversing in closing movement
2
Reversing in closing and during time in C492, Change of direction delay
S
C449 Reversing during run-on time or disengagement
angle with
load guard
triggered, L117, L127, L213,
L223
0 - 1
1
0
No reversing
1
Reversing in closing movement
C460
Time delay before second motor starts.
Start of motor 2 is delayed during opening
Start of motor 1 is delayed during closing
0.1-9.9 seconds
0.1
C470
Time delay before first motor starts.
Start of motor 1 is delayed during opening
Start of motor 2 is delayed during closing
0.00-0.99 seconds
0.00
S
C492 Reverse delay if PHOTO, SL1 or SL2 or control
signal are activated.
0.1-4.0 seconds
0.8
S
C493 Reverse delay if safety edge or load guard are
activated
0.03-2.00 seconds
0.10
S
C494 Closing time after activated protection function,
safety edge or load guard, while opening
0.1-2.0 seconds
1.0
C495
Engagement time for brake, motor 1
00, 10-50 ms
00
C496
Engagement time for brake, motor 2
00, 10-50 ms
00