background image

ZXT-510 

AC MASTER 
Lite

 

INSTALLATION GUIDE 

 

 

 

 
 
 

 

 

Summary of Contents for AC MASTER LITE

Page 1: ...ZXT 510 AC MASTER Lite INSTALLATION GUIDE...

Page 2: ......

Page 3: ...3 Setup Automatic Status Report Association to Gateway 7 Step 4 Setup Air Conditioner IR code 7 Other Setup Options through Configuration 14 Support for Association Groups 17 Reset to Factory Default...

Page 4: ...2 Caution 23...

Page 5: ...loud stored IR database library ZXT 510 can control different brands and models of air conditioners worldwide ZXT 510 is a security enabled Z Wave plus device A security Enabled Z Wave Plus Controller...

Page 6: ...4 Product Overview...

Page 7: ...l interchangeable when setting up your Z Wave network Inclusion Add a Z Wave device to the network Exclusion Remove a Z Wave device from the network Remove To take a device out of a group scene or ass...

Page 8: ...Rout ing Slave FLiRS mode is targeted for battery operated applica tions and will enter sleep mode frequently in order to conserve battery consumption The response to Z Wave command is not as quick as...

Page 9: ...ing or awake cannot be changed unless it is exclud ed and re apply the power ZXT 510 can be included and operated in any Z Wave network with other Z Wave certified devices from other manufacturers and...

Page 10: ...oup 1 max 1 node is default to associate with the primary controller Gateway Hub Controller for AC Master Status change report refer to below for report details Current Room Temperature report in prec...

Page 11: ...9 and Con figuration Command Class You may refer to below steps to setup the IR code using the configuration options in your gateway...

Page 12: ...eat Step 2 and 3 to Select the next IR Code on the search list Green Indicator flashes ONCE every time i f receives a command from Gateway Important Information Different brand or model of air conditi...

Page 13: ...urns ON for in dicating the IR Code Learning Start 4 Aim the Original Air Conditioner Remote at AC Master according to below position within 1 3cm Press Power ON button on the Original Air Conditioner...

Page 14: ...model Keep away from Incandescent Light or Direct Sunlight during learning Make sure IR Transmitter of your Original Remote alight with learning diode of AC Master you may also slight adjust closer o...

Page 15: ...COOL 68 F or 69 F COOL 6 21 C COOL 70 F or 71 F COOL 7 22 C COOL 72 F or 73 F COOL 8 23 C COOL 74 F or 75 F COOL 9 24 C COOL 76 F COOL 10 25 C COOL 77 F or 78 F COOL 11 26 C COOL 79 F or 80 F COOL 12...

Page 16: ...76 F HEAT 24 25 C HEAT 77 F or 78 F HEAT 25 26 C HEAT 79 F or 80 F HEAT 26 27 C HEAT 81 F or 82 F HEAT 27 28 C HEAT 83 F or 84 F HEAT 28 29 C HEAT 85 F HEAT 29 30 C HEAT 86 F HEAT 30 DRY MODE DRY MOD...

Page 17: ...l use gateway to set up Scene and Schedule with ZXT 510 For example to have AC turn on at 23 C every day at 7am 25 C at 11pm Just make sure the set code is learnt The learning mapping table is for spl...

Page 18: ...0x00 to 0x04 0 0x00 Idle IR Channel is idle 1 0x01 OK the last learning opera tion was completed successfully 2 0x02 Learning ZXT 510 is busy processing previous learning request 3 0x03 Full All locat...

Page 19: ...m user can disable the built in IR emitter and use the exter nal IR emitter cable to control each air conditioner 32 0x20 Default 0xFF 0 or 255 0x00 or 0xFF 0 0x00 Disable 255 0xFF Enable Default 1 Co...

Page 20: ...x1E 0 0x00 Disable AUTO report func tion Default for saving battery life Auto report if room temperature is different from last report 1 0x01 1 F 0 5 C 2 0x02 2 F 1 C 3 0x03 3 F 1 5 C 4 0x04 4 F 2 C 5...

Page 21: ...cimal numbering format please change it to deci mal value accordingly Mapping Information BASIC Set Value 0x00 will map to Thermostat mode OFF 0x00 BASIC Set Value 0xFF will map to Thermostat mode Res...

Page 22: ...k primary controller is missing or otherwise inop erable Mounting Required tools and supplies Phillips Screwdriver Drill Drill bit 3 16 for drywall 7 32 for plaster Hammer Pencil Level optional AA Alk...

Page 23: ...ucture of the mounting location If the location does not have the proper material or struc ture the ZXT 510 can fall and cause an injury Avoid mounting above or near hot surfaces or equipment e g TV H...

Page 24: ...z ZXT 510KR 865 2MHz ZXT 510IN 868 4MHz ZXT 510CN RF Operating Distance Up to 132ft outdoor line of sight in unobstructed environment Temperature Measuremen t Measurable range 0 C 40 C 32 F 104 F Repo...

Page 25: ...d parties and any property damage or personal injuries arising from or related to the use of the device Service trips to provide instruction on product use Shipping costs for replacement products This...

Page 26: ...d and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If thi...

Page 27: ...l appareil ne doit pas produire de brouillage et l utilisateur de l appareil doit accepter tout brouillage radio lec trique subi m me si le brouillage est susceptible d en comprom ettre le fonctionnem...

Reviews: