Service Manual_AVA1_ENG-20220922_I
94
Revision Check
Revision Check >
Revision
Overview
Display of the revision of the printer configuration (8-digit)
Adj/Set/Ope
rate Method
N/A (Display only)
Rbn Back
Tension
Overview
Set of the duty of the Ribbon Supply Motor (DM2) at the primary
transfer
Detail
Set the duty of the Ribbon Supply Motor (DM2) at the primary
transfer.
Adj/Set/Ope
rate Method
1.
Select the setting value.
2.
Press the SET key, and then confirm the setting value.
Caution
Do not change "REVSION 0 ".
Display/Adj/
Set Range
REVSION 0
REVSION 1
Default Value REVSION 0
Ribbn Tension Overview
Set of the duty of the Ribbon Wind Up Motor (DM1) at the primary
transfer
Detail
Set the duty of the Ribbon Wind Up Motor (DM1) at the primary
transfer. Set the value depending on the stripping mechanism of
the primary transferring.
•
REVSION 0: flat stripping shaft
•
REVSION 1: stepped stripping shaft
Adj/Set/Ope
rate Method
1.
Select the setting value.
2.
Press the SET key, and then confirm the setting value.
Display/Adj/
Set Range
REVSION 0
REVSION 1
Platen Nip Duty Overview
Set the duty of the Platen Lift Motor (DM5)
Detail
Set the duty of the Platen Lift Motor (DM5). Set the value depending
on the platen elevating mechanism of the Printhead.
•
0: if there is no cam follower bearing.
•
1: if there is a cam follower bearing.
Adj/Set/Ope
rate Method
1.
Select the setting value.
2.
Press the SET key, and then confirm the setting value.
Display/Adj/
Set Range
REVSION 0
REVSION 1
Thermister
Overview
Set of the thermistor configuration
Detail
Set the thermistor configuration. Set the value depending on the
presence of the Outer Air Thermistor (TM4).
•
0: if there is not the Outer Air Thermistor (TM4).
•
1: if there is the Outer Air Thermistor (TM4).
Adj/Set/Ope
rate Method
1.
Select the setting value.
2.
Press the SET key, and then confirm the setting value.
Display/Adj/
Set Range
REVSION 0
REVSION 1
Supplement/M
emo
When 0 is set, the printer operates with an ambient temperature
setting of 23 deg C.
Heat Roller
Overview
Set of the kind of the heat roller
Heat Roller
Detail
Set the value depending on the heat roller.
•
0: initial version
•
1: version upgrade of revision 0
•
2: discontinuance of revision 1
Adj/Set/Ope
rate Method
1.
Select the setting value.
2.
Press the SET key, and then confirm the setting value.
Display/Adj/
Set Range
REVSION 0
REVSION 1
REVSION 2
Summary of Contents for AV1H0000BD
Page 1: ...Service Manual_AVA1_ENG 20220922_I 1 AVANSIA SERVICE MANUAL...
Page 73: ...Service Manual_AVA1_ENG 20220922_I 73 Drawing 9 HEAT ROLLER CP011845 HEAT ROLLER MODULE S10248...
Page 74: ...Service Manual_AVA1_ENG 20220922_I 74 Drawing 10 DECURL MODULE CP011976 DECURL SPRING CP011978...
Page 76: ...Service Manual_AVA1_ENG 20220922_I 76 Drawing 12 PACKAGING BOX AND FOAM S10205...
Page 109: ...Service Manual_AVA1_ENG 20220922_I 109 Tools required...
Page 118: ...Service Manual_AVA1_ENG 20220922_I 118 6 Move the hinge outwards 7 Remove the two screws...
Page 133: ...Service Manual_AVA1_ENG 20220922_I 133 8 Unplug the two sensors 9 Remove the three screws...
Page 135: ...Service Manual_AVA1_ENG 20220922_I 135 12 Remove the heat roller horizontally...
Page 139: ...Service Manual_AVA1_ENG 20220922_I 139 6 Remove the V ring 7 Remove the axis...
Page 158: ...Service Manual_AVA1_ENG 20220922_I 158 7 Remove the two screws...
Page 167: ...Service Manual_AVA1_ENG 20220922_I 167 13 Unplug these cables 14 Open the cables holder...
Page 221: ...Service Manual_AVA1_ENG 20220922_I 221 8 Close the front cover...
Page 275: ...Service Manual_AVA1_ENG 20220922_I 275 Printer details Ribbon details...
Page 286: ...Service Manual_AVA1_ENG 20220922_I 286 BLOCK PLAN FOR ELECTRIC PARTS...
Page 287: ...Service Manual_AVA1_ENG 20220922_I 287...
Page 288: ...Service Manual_AVA1_ENG 20220922_I 288...
Page 289: ...Service Manual_AVA1_ENG 20220922_I 289...
Page 290: ...Service Manual_AVA1_ENG 20220922_I 290...
Page 291: ...Service Manual_AVA1_ENG 20220922_I 291 MAIN BOARD PLAN...
Page 293: ...Service Manual_AVA1_ENG 20220922_I 293 www evolis com...