Hub van Doorneweg 8 • 2171 KZ Sassenheim – NL •
T
+31(0)252 228850 •
F
+31(0)252 228235 •
E
I
euronormdrives.com
Hub van Doorneweg 8 • 2171 KZ Sassenheim – NL •
T
+31(0)252 228850 •
F
+31(0)252 228235 •
E
I
euronormdrives.com
96
97
NEURN030000_220_A
NEURN030000_220_A
V-12 Frequency reference mode(External potentiometer, keyboard encoder) switching
V-12-1 Electrical diagram:
(Default)
380V 50/60Hz
Three phase input power supply
Circuit breaker
FWD/STOP
Primary and secondary switching of frequency source
Motor
M
%
Frequency given mode
(external potentiometer, keyboard encoder) switching
V-12-2 Parameter setting
No.
Code
Parameter name
Setting range
F0.03
Frequency source master setting
Panel potentiometer setting
4
F0.04
Frequency source auxiliary setting
AI1analog quantity setting
2
F0.11
Command source selection
Terminal block control (LED on)
1
F1.00
DI1 terminal function selection
Forward run (FWD)
1
F1.02
DI3 terminal function selection
Frequency source switching
18
F0.07
Frequency source
superimposed selection
Frequency reference main / auxiliary
switching
02
Note:
DI3 and COM connected to an external potentiometer speed control, disconnect the panel potentiometer speed.