Hub van Doorneweg 8 • 2171 KZ Sassenheim – NL •
T
+31(0)252 228850 •
F
+31(0)252 228235 •
E
I
euronormdrives.com
90
91
NEURN030000_220_A
NEURN030000_220_A
V-6 External potentiometer speed
V-6-1 Electrical diagram:
(Default)
Circuit breaker
380V 50/60Hz
Three phase input power supply
FWD/STOP
Motor
M
%
Speed regulation of external potentiometer
V-6-2 Connection:
The three cables of potentiometers are connected to the in10 V, AI1, GND terminal, note that the direction of
potentiometer wiring, clockwise to the maximum corresponding maximum frequency, counterclockwise twisted to the
minimum corresponding 0Hz.
V-6-3 Parameter setting
No.
Code
Parameter name
Setting
range
F0.03
Frequency source master setting
Analog AI1 setting
2
F0.11
Command source selection
Terminal block control (LED on)
1
F1.00
DI1 terminal function selection
Forward run (FWD)
1
V-7 Keyboard potentiometer speed
Parameter setting:
No.
Code
Parameter name
Setting
range
F0.03
Frequency source master setting
Panel potentiometer setting
4
F1.42
Keyboard potentiometer X2
0~100.00%
1.00
Note:
F1.42 is used to adjust the rate of change of panel potentiometer rotation frequency.
The smaller this value is, the more sensitive the panel potentiometer rotation frequency changes.