Appendix IV: Instruction of Profitbus –DP communication card
IV-1 Outline
9KDP1 meet the international standard PROFIBUS fieldbus, Euronorm technology JI500 series inverter use it together to
achieve the drive to become a part of fieldbus complete control of real fieldbus. Before using this product, please carefully
read this manual.
IV-2 Terminal function
IV-2-1 DIP switch description
Switch position No.
Function
Instruction
1,2
DP Card and the drive
baud rate selection
Bit 1
Bit 2
Baud Rate
OFF
OFF
115.2K
OFF
ON
208.3K
ON
OFF
256K
ON
ON
512K
3-8
Profibus-DP Com-
munication from the
station address
6 Binary Consisting of 64-bit binary address, more than 64 outside the address can be set
only by function code. The following lists some slave address and switch settings
Address switch settings
0 00 0000
7 00 0111
20 01 0100
Table V-1: Switch Functions
IV-2-2 Terminal Function
1) External communication terminal J4-6PIN
Terminal NO
Mark
Function
Terminal NO
Logo
Function
1
GND
5V power ground
4
TR+
Cable Positive
2
RTS
Request to send signal
5
+5V
5Vpower
3
TR-
Cable negative
6
E
The grounding end
Table V-2: External communication terminal function
2) Upper machine communication interface SW1-8PIN
Terminal No
Terminal logo
Function
Terminal No
Terminal logo
Function
1
BOOT0
ARM boot selection
5
PC232T
PC 232 communication Sending side
2
GND
Power ground
6
PC232R
PC 232 communication receiving side
3
VCC
Power
7
RREST
ARM reset
4
Reserved
Reserve
8
GND
Power ground
Table V-3: PC communication terminal function
IV-2-3 LED Light function
LEDlight
Function definition
Description
Green
Power light
If DP card and drive interfaces connected, the inverter after power LED should be in the steady state
Red
DP CARDS and frequency
converter serial port con-
nect light
DP Card and inverter connected to the normal state of the LED is lit, flashing indicates the connec-
tion is intermittent (For interference), and drive off when a serial connection is unsuccessful
(You can check the baud rate setting)
Yellow
DP card and Profibusmain
connection indicator light
DP Profibus master card and connect normal state of the indicator is lit. flashing indicates the con-
nection is intermittent (For interference), and Profibus master is off when connection is unsuccessful
(you can check the slave address, data formats, and Profibus cable )
Table V-4: LED light function description