Hub van Doorneweg 8 • 2171 KZ Sassenheim – NL •
T
+31(0)252 228850 •
F
+31(0)252 228235 •
E
I
euronormdrives.com
Hub van Doorneweg 8 • 2171 KZ Sassenheim – NL •
T
+31(0)252 228850 •
F
+31(0)252 228235 •
E
I
euronormdrives.com
48
49
NEURN030000_220_A
NEURN030000_220_A
7.1.19 b0 Group -Motor parameters
Code
Parameter name
Setting range
Factory
setting
Change
b0.00
Motor type selection
0: General asynchronous motor
1: Asynchronous inverter motor
2: Retain
0
★
b0.01
Rated power
0.1kW~1000.0kW
Depends on
models
★
b0.02
Rated voltage
1V~2000V
Depends on
models
★
b0.03
Rated current
0.01A~655.35A (Inverter power
≦
55kW)
0.1A~6553.5A (Inverter rate> 55kW)
Depends on
models
★
b0.04
Rated frequency
0.01Hz~F0.19 (Maximum frequency)
Depends on
models
★
b0.05
Rated speed
1rpm~36000rpm
Depends on
models
★
b0.06
Asynchronous motor stator resistance
0.001Ω~65.535Ω (Inverter power <= 55kW)
0.0001Ω~6.5535Ω (Inverter power> 55kW)
Motor
parameters
★
b0.07
Asynchronous motor rotor resistance
0.001Ω~65.535Ω (Inverter power <= 55kW)
0.0001Ω~6.5535Ω (Inverter power> 55kW)
Motor
parameters
★
b0.08
Asynchronous motor leakage inductance
0.01mH~655.35mH (Inverter power <= 55kW)
0.001mH~65.535mH (Inverter power> 55kW)
Motor
parameters
★
b0.09
Asynchronous motor mutUal inductance
0.1mH~6553.5mH (Inverter power <= 55kW)
0.01mH~655.35mH (Inverter power> 55kW)
Motor
parameters
★
b0.10
Asynchronous motor no-load current
0.01A~b0.03 (Inverter power <= 55kW)
0.1A~b0.03 (Inverter power> 55kW)
Motor
parameters
★
b0.27
Motor parameter auto tunning
0: No operation
1: Asynchronous motor parameters still auto
tunning
2: Asynchronous motor parameters
comprehensive auto tunning
11: Synchronous motor parameters still auto
tunning
12: Synchronous motor parameters
comprehensive auto tunning
0
★
b0.28
Encoder type
0: ABZ incremental encoder
1: UVW incremental encoder
2: Rotational transformer
3: Sine and cosine encoder
4: Wire-saving UVW encoder
0
★
b0.29
Encoder every turn pulse number
1~65535
2500
★
b0.30
Encoder installation angle
0.00~359.90
0.00
★
b0.31
ABZ incremental encoder AB phase sequence
0: Forward
1: Reverse
0
★
b0.32
UVW encoder offset angle
0.00~359.90
0.0
★
b0.33
UVW encoder UVW phase sequence
0: Forward
1: Reverse
0
★
b0.34
Speed feedback PG disconnection detection
time
0.0s: OFF
0.1s~10.0s
0.0s
★
b0.35
Pole-pairs of rotary transformer
1~65535
1
★