Switch between
frequency source
master setting and
preset frequency
When the terminal is active, the frequency source A is replaced by the preset frequency (F0.01)
40
Switch between
frequency source
auxiliary setting and
preset frequency
When the terminal is active, the frequency source B is replaced with the preset frequency (F0.01)
41
Reserve
42
Reserve
43
PID parameter
switching
When DI terminal (E2.19 = 1) is used to switch PID parameters, if the terminal is invalid, PID parameters
use E2.13~ E2.15; if the terminal is valid, PID parameters use E2.16 ~ E2.18
44
Custom fault 1
When custom fault 1 and custom fault 2 are active, the inverter respectively alarms fault Err.27 and fault
Err.28, and deals with them according to the mode selected by the fault protection action F8.19.
45
Custom fault 2
46
Speed control
/ torque control
switching
Switch between speed control mode and torque control mode under vector control mode. If the
terminal is invalid, the inverter will run at the mode defined by FA.00 (Speed/torque control mode);
if the terminal is valid, the inverter will be switched to another mode.
47
Emergency parking
If the terminal is valid, the inverter will park at the fastest speed, and the current maintains at the set
upper limit during the parking process. This function is used to meet the requirements that the inverter
needs to stop as soon as possible when the system is in a emergency state.
48
External parking
terminal 2
In any control mode (Keyboard control, terminal control, communication control), the terminal can be
used to decelerate the inverter until stop, at the time the deceleration time is fixed for deceleration time 4.
49
Deceleration DC
braking
If the terminal is valid, firstly the inverter decelerates to the initial frequency of stop DC braking, and then
switches directly to DC braking status.
50
Clear current running
time
If the terminal is valid, the inverter’s current running time is cleared
51
Jog order
Jog running order,direction set through F7.54
F1.10
Terminal command mode
0: Two-wire type 1; 1: Two-wire type 2
2: Three-wire type 1; 3: Three-wire type 2
0
★
F1.11
Terminal UP/DOWN change rate
0.001Hz/s ~65.535Hz/s
1.000Hz/s
☆
F1.12
Minimum input for AIC1
0.00V ~F1.14
0.30V
☆
F1.13
F1.12corresponding setting
-100.0% ~+100.0%
0.0%
☆
F1.14
Maximum input for AIC1
F1.12 ~+10.00V
10.00V
☆
F1.15
F1.14corresponding setting
-100.0% ~+100.0%
100.0%
☆
F1.16
Minimum input for AIC2
0.00V ~F1.18
0.00V
☆
F1.17
F1.16corresponding setting
-100.0% ~+100.0%
0.0%
☆
F1.18
Maximum input for AIC2
F1.16 ~+10.00V
10.00V
☆
F1.19
F1.18corresponding setting
-100.0% ~+100.0%
100.0%
☆
F1.20
Minimum input for AIC3
-10.00V ~F1.22
0.00V
☆
F1.21
F1.20corresponding setting
-100.0% ~+100.0%
0.0%
☆
F1.22
Maximum input for AIC 3
F1.20 ~+10.00V
10.00V
☆
F1.23
F1.22corresponding setting
-100.0% ~+100.0%
100.0%
☆
F1.24
AIcurve selection
Units digit: AI1 curve selection
Tens digit: AI2 curve selection
Hundreds digit:panel potentiometer curve selection
321
☆
F1.25
Setting selection for AI input
Units digit: Setting selection for AI1 less than minimum input
0: Corresponding to minimum setting
1: 0.0%
Tens digit: Setting selection for AI2 less than minimum input, ditto
Hundreds digit: Setting selection for AI3 less than minimum
input(0 ~ 1,ditto)
000
☆
F1.26
HDI Minimum pulse input
0.00kHz~F1.28
0.00kHz
☆
F1.27
F1.26 corresponding setting
-100.0%~+100.0%
0.0%
☆
F1.28
HDI Maximum input
F1.26~100.00kHz
50.00kHz
☆
F1.29
F1.28 corresponding setting
-100.0%~+100.0%
100.0%
☆
F1.30
DI filter time
0.000s~1.000s
0.010s
☆
F1.31
AI1 filter time
0.00s~10.00s
0.10s
☆
F1.32
AI2 filter time
0.00s~10.00s
0.10s
☆