Operation & Software Manual
302
Direct Drives & Systems
Chapter E: Appendixes
ETEL Doc. - Operation & Software Manual # DSC2P 903 / Ver. F / 3/6/05
DSCDL
p
aram
eters
K190
Global enable of real-time function
0
0
1
K191
List of valid real-time lines in the RTI table
0
0
255
K192
List of enable real-time lines in the RTI table
0
0
255
K193
List of pending real-time lines in the RTI table
0
0
255
K194
Time added at the end of the movement where K60 is
kept as force/torque reference. At the end of this time,
K59 is kept as force/torque reference
0
0
600000
K198
The register number is given by K198 when it is equal to
Y or y (ex: Ky.1=...). See EBL2 manual
0
0
65535
K201
MMC
Concatenated movement selection
0
0
3
0
Concatenated movement disabled
1
Concatenated movement enabled for MMD=1, 17 and
24
2
Continuous back and forth movement enabled for MMD
= 10, 26, 3 and 19 movement (could be stopped by POS,
BRK, HLT, HLB and HLO commands)
3
One back and forth MMD = 10, 26, 3 and 19 movement
enabled for look-up table movement
K202
MMD
Movement type
1
1
32
1
S-curve (jerk time) linear movement
3
Selects a predefined linear movement according to K230
value and executes the trajectory in a time given by
K229
10
Look-up table linear movement
17
S-curve (jerk time) rotary movement
19
Selects a predefined rotary movement according to
K230 value and executes the trajectory in a time given
by K229
24
Infinite rotary movement
26
LKT rotary movement
K203
LTN
Look-up table number movement
0
0
7
K204
LTI
Time to execute a look-up table movement
10000
4
500000
K205
CAM
Came value (in percent). Stretches the user time scale
100
1
100
K206
Brake deceleration (with BRK and HLB command)
1000000
256
2147483647
K207
LKT mode selection
0
0
1
0
LKT movement running to target defined by POS
command
1
LKT movement with same starting and end point. K208
defines the amplitude of the movement
K208
Maximum stroke for LKT movement with K207=1 and for
MMD=10 & 26
0
-2147483648 2147483647
K209
Rotary movement type selection
0
0
2
0
Movement always positive
1
Movement always negative
2
Movement minimum distance
K210
POS
Starts movement (only depth 0) and gives the target
position
0
-2147483648 2147483647
K211
SPD
Absolute maximum speed
2000000
1
2147483647
K212
ACC
Absolute maximum acceleration and deceleration
1000000
256
2147483647
K
Alias
Val
<P1>
Bit #
<P1>
Comment for parameters K
and <P1> of the DSCDL
Def. Val
<P1>
Min. Val
<P1>
Max. Val
<P1>