ETEL Doc. - Operation & Software Manual # DSC2P 903 / Ver. F / 3/6/05
Chapter E: Appendixes
Operation & Software Manual
Direct Drives & Systems
317
DSC
2P and
DSC2V mo
nit
o
ring
s
94
Error auxiliary channel second command Macro
95
Error auxiliary channel Macro aux 2
96
Error auxiliary channel Macro aux 3
97
Error auxiliary channel Macro aux 4
100
Optional board error 100. See optional board manual
101
Optional board error 101. See optional board manual
102
Optional board error 102. See optional board manual
103
Optional board error 103. See optional board manual
104
Optional board error 104. See optional board manual
105
Optional board error 105. See optional board manual
106
Optional board error 106. See optional board manual
107
Optional board error 107. See optional board manual
108
Optional board error 108. See optional board manual
109
Optional board error 109. See optional board manual
110
Optional board error 110. See optional board manual
111
Optional board error 111. See optional board manual
112
Optional board error 112. See optional board manual
113
Optional board error 113. See optional board manual
114
Optional board error 114. See optional board manual
115
Optional board error 115. See optional board manual
116
This error is generated by the ERR command. In
general, this command is sent by the DSMAX or the
u-master
130
Hardware overcurrent. The current has reached the
maximum admissible value by the controller
141
Watchdog error
144
The difference between the oscillator and quartz is too
big
150
Bad measure during the phasing process when K90=1
151
Bad time measurement during phasing process when
K90=1
152
Error when the controller is disabled during
phasing process when K90 = 1 or 2
153
Too low force when K90=6
154
Too high force when K90=6
155
Too low time when K90=6
156
Time-out during AUT command
157
Error during the phasing process when K90=2
190
The controller has executed a save operation (SAV
command)
M66
Gives the warning code
0
0
255
1
This warning occurs when M67 is greater than K85/2
2
This warning occurs when the temperature of the
controller is greater than 60°C
M
Alias
Values
Bit #
<P1>
Comment for monitorings M
and <P1> of the DSC2P and DSC2V
Def. Val
<P1>
Min. Val
<P1>
Max. Val
<P1>