K139
Optional board parameter (see optional board manual)
0
-2147483648 2147483647
K140
Mask for fuse control
0
0
1
1
0
Disables the test of F2 fuse
K141
Enables test of motor overtemperature protection
connected to DIN and test of TEB time-out error. K141 is
a global parameter (for both axes), it is only available on
pair axis (for example: K141.0=2 is available, K141.1=2
is not available)
0
0
122
2
1
Enables time-out TEB error test
8
3
Enables test of motor overtemperature protection,
connected to DIN1
16
4
Enables test of motor overtemperature protection,
connected to DIN2
32
5
Enables test of motor overtemperature protection,
connected to DIN9
64
6
Enables test of motor overtemperature protection,
connected to DIN10
K145
Searches limit stroke (SLS) mode
0
0
3
0
Positive movement to search mechanical end stop
1
Negative movement to search mechanical end stop
2
Positive movement to search mechanical limit switch
3
Negative movement to search mechanical limit switch
K146
Limit of Vpower to activate undervoltage warning [V/
100]. When Vpower[V] * 100 is lower than K146, the
controller generates an undervoltage warning (M66=10).
If K146=0, the limit detection is disabled
1200
0
4000
K147
Limit of Vpower to activate undervoltage error [V/100].
When Vpower[V] * 100 is lower than K147, the controller
generates an undervoltage error (M64=9). If K147=0, the
limit detection is disabled
800
0
4000
K148
Limit of Vpower to activate overvoltage warning [V/100].
When Vpower[V] * 100 is greater than K148, the
controller generates an overvoltage warning (Set bit#19
of SD1). If K148=0, the limit detection is disabled. For
DSC2P the limit is reduced by firmware
3700
0
4000
K149
Limitt of Vpower to activate overvoltage error [V/100].
When Vpower[V] * 100 is greater than K149, the
controller generates an overvoltage error (M64=6). If
K149=0, the limit detection is disabled.
3800
0
4000
K150
MST
Optional board source register type. It has four depths to
monitor four registers per sti (slow time interrupt)
0
0
3
1
Source type is a user's variable X
2
Source type is a parameter K
3
Source type is a monitoring M
K151
MSN
Optional board source register index
0
0
255
K154
MOF
Optional board source register offset
0
-2147483647 2147483647
K155
MAM
Optional board source register gain
16777216
-2147483647 2147483647
K156
DAO
Optional board analog offset. It has 4 depths for DSO-
HIO analog output, each depth corresponds to the
depths of K173
0
-32767
32767
K157
DAA
Optional board analog gain. It has 4 depths, for DSO-
HIO analog output, each depth corresponds to the
depths of K173
32767
-32767
32767
K
Alias
Val
<P1>
Bit #
<P1>
Comment for parameters K
and <P1> of the DSCDL
Def. Val