ETEL Doc. - Operation & Software Manual # DSC2P 903 / Ver. F / 3/6/05
Chapter C: System functions
Operation & Software Manual
Direct Drives & Systems
109
stored in parameter K53 (phase shift adjustment).
Caution:
When parameter K90 or K68 is modified, the command AUT = 10 must be executed to re-
calculate parameter K53.
•
K90 = 5: Phasing and commutation with digital Hall effect sensor only
The commutation is only done with the digital Hall effect sensor.
Caution:
When parameter K90 or K68 is modified, the command AUT = 10 must be executed to re-calculate
parameter K53.
Remark:
Refer to the corresponding
’Hardware Manual’
for more information about the connection of the
Hall effect sensor.
Available on
DSC2P
DSC2V
DSCDP
DSCDL
DSCDM
MOTOR
ENCODER
Reference mark
Encoder with K53 (LKT)
Hall
Encoder
MOTOR
Encoder with K53 (LKT)
Hall