ETEL Doc. - Operation & Software Manual # DSC2P 903 / Ver. F / 3/6/05
Chapter E: Appendixes
Operation & Software Manual
Direct Drives & Systems
319
DSC2P and
DSC2V m
o
n
itorin
g
s
M91
DC power voltage (Vpower) [V*100]. M91/100 gives
the tension in Volt
0
0
100000
M95
Shows the strings on the display. The 16 strings of the
controller display are read using the 4 depths of M95.
Each depth shows 4 string (in ASCII)
0
0
4294967295
M96
Gives the line number being executed in the sequence
0
0
8190
M110
Gives the interpolation mode of the position controller
0
0
255
0
Interpolation mode disabled
1
Interpolation mode at every sti interrupt. Takes jerk
time (IJT) and encoder scaling/mapping into account
2
Interpolation mode on fti interrupt. Does not take jerk
time (IJT) and encoder scaling/mapping into account
M140
Fuse status
0
0
1
1
0
Fuse F3 broken (from DSC2Pxxx-xxxC-xxxx)
M145
Type of EnDat encoder
0
0
65535
M146
EnDat measuring step per turn (for rotary encoder) or
in [mm] (for linear encoder)
0
0
65535
M147
EnDat analog encoder period per turn (for rotary
encoder) or in [mm] (for linear encoder)
0
0
65535
M148
EnDat pulse number
0
0
65535
M149
EnDat turn number
0
0
65535
M171
Gives the state of the digital outputs of the controller.
Takes DOUT (K171) and K37 into account
0
0
15
M173
Real state of DSO-HIO analog output 1. Takes K173,
K150, K151 and K154 to K157 into account
0
-8192
8191
M174
Real state of DSO-HIO analog output 2. Takes K173,
K150, K151 and K154 to K157 into account
0
-8192
8191
M175
Real state of DSO-HIO analog output 3. Takes K173,
K150, K151 and K154 to K157 into account
0
-8192
8191
M176
Real state of DSO-HIO analog output 4. Takes K173,
K150, K151 and K154 to K157 into account
0
-8192
8191
M230
Real-time monitoring 1 slave to slave
0
0
4294967295
M231
Real-time monitoring 2 slave to slave
0
0
4294967295
M239
Encoder period
1
1
2147483647
M240
Motor type
0
0
1
M241
Encoder interpolation factor
0
0
32768
M242
Controller quartz frequency [Hz]
30000000
30000000
30000000
M243
Controller current loop time factor (cti). M243/M242 =
time in second
1250
1250
1250
M244
Controller position loop time factor (fti). M244/M242 =
time in second
1250
1250
1250
M245
Controller slow interrupt time factor (sti). M245/M242 =
time in second
5000
5000
5000
M
Alias
Values
Bit #
<P1>
Comment for monitorings M
and <P1> of the DSC2P and DSC2V
Def. Val
<P1>
Min. Val
<P1>
Max. Val
<P1>