19.3 Errors for DSCDL
DSCD
P er
ro
rs
144
QUARTZ
OSCILLAT
Difference between the oscillator
and quartz is too big
x
x
OFF
150
INITIALI
MOTOR 1
Bad measure during initialization
process when K90=1
x
K90, K91,
K98
Motor cable
x
OFF
151
INITIALI
MOTOR 2
Bad time measurement during
initialization process when K90=1
x
K90, K91,
K98
Motor cable
x
OFF
152
INITIALI
POWER OF
Error when the controller is disabled
during initialization process when
K90=1 or 2
x
OFF
153
INITIALI LOW
CUR
Too low force when K90 = 6.
Increase K91
K91,
K101
x
OFF
154
INITIALI
HIGH CUR
Too high force when K90 = 6.
Decrease K91
K91,
K101
x
OFF
155
INITIALI LOW
TIME
Too low time when K90 = 6. Increase
K101
K91,
K101
x
OFF
156
TIMEOUT
AUT CMD
Time-out during AUT command
x
x
K90 to
K98 K79
Motor or
encoder cable
x
OFF
157
INIT BAD
PHASING
Error during the initialization
process when K90=2
x
x
K90 to
K98 K79
Motor or
encoder cable
x
OFF
190
SWITCH OFF
& ON
The controller has executed a save
operation (SAV command)
x
OFF
M64
Displayed
message
Description
Enc Mot Hrd
Bad K PS TEB EBL2
Other
SW
res
Hw
res
Brk
DSCDL
errors
2
OVER
CURRENT1
The current measured in phase 1 is
greater than K83
x
x
K60, K80,
K81, K83,
K98
x
OFF
3
OVER
CURRENT2
The current measured in phase 2 is
greater than K83
x
x
K60, K80,
K81, K83,
K98
x
OFF
4
I2T ERROR
This occurs when M67 becomes
greater than K85. This is a power
protection (of the motor and/or the
controller)
K1, K2,
K4, K52,
K53, K56,
K84, K85
Friction / duty
cycle
x
OFF
5
OVER
TEMPERAT
The temperature of the controller is
greater than 70°C. This is measured
by a thermostat mounted on the heat
sink
Heat evacuation x
OFF
6
OVER
VOLTAGE
The power voltage (Vpower) in volt
in greater than K149/100
K149
x
OFF
8
+5V
SHUTDOWN
Error that occurs when the +5V of
the controller becomes lower than
4.5V
x
x
x
OFF
9
UNDER
VOLTAGE
The power voltage (Vpower) in volt is
lower than K147/100
K147
x
OFF
10
OFFSET
CURERROR
Error in offset of current
measurement. The offset measured
is greater than 8% of the maximum
current of the controller (M82)
x
x
OFF
13
SENSOR
TEMP ERR
The temperature sensor does not
respond
x
x
OFF
16
ENDAT
OVERFLOW
The calculated EnDat position is too
big. Decrease K77
x
K77
x
ON
M64
Displayed
message
Description
Enc Mot Hrd
Bad K PS TEB EBL2
Other
SW
res
Hw
res
Brk