Operation & Software Manual
180
Direct Drives & Systems
Chapter C: System functions
ETEL Doc. - Operation & Software Manual # DSC2P 903 / Ver. F / 3/6/05
Monitorings M173, M174, M175 and M176 allow the user to read the value of the 4 analog outputs by taking
parameters K154 to K157 into account:
Here is the formula giving the values on the analog outputs after the amplitude and offset correction (M17x is
M173, M174, M175 or M176 depending on the output number):
Remark:
It is possible to invert the signal with negative values.
Example with K154 = 1000, K155 = 2
23
, K156 = 100, K157 = 2
14
and a DAC with an offset of -50 inc.
M
Name
Comment
M173
Analog output1 status
Gives the value on the analog output 1
M174
Analog output2 status
Gives the value on the analog output 2
M175
Analog output3 status
Gives the value on the analog output 3
M176
Analog output4 status
Gives the value on the analog output 4