ETEL Doc. - Operation & Software Manual # DSC2P 903 / Ver. F / 3/6/05
Chapter B: System setup & tuning
Operation & Software Manual
Direct Drives & Systems
37
Example with a DSC2P:
Warning:
Risk of electrical shock!
High voltage may be present on the motor connector. Turn off the
power,
wait 10 minutes (or 2min for the DSCDM)
and
before touching them,
check with a
voltmeter that no residual voltage remains on these connectors!
7.1.2
Configuration with a DSMAX or a DSTEB
For a configuration with a DSMAX or a DSTEB, plug the connectors as listed below:
• When the connections are realized, turn on the power supply.
• The controller performs a SELF TEST and will display on the LCD its: controller family, product number,
firmware version present in the controller, axis number, presence of an optional board,....
• A message (for example: DSC2P READY) appears on the LCD display (the controller is not in the POWER
ON mode).
Never connect the motor if
POWER ON
already appears on the LCD display!
Remark:
If there is no physical display on the controllers, the user can use M95.<axis> (the conversion is
automatically done by the DLLs) or can select ’scope drive LCD display’ in the ’scope’ menu of
the scope tools (ETT) to display a software display indicating the status, the error and the warning
messages.
• The system is ready to work.
Interfaces to be connected
Required
Optional
1) TEB communication (refer to the corresponding
'Hardware Manual'
to know the connector number)
X
2) Position encoder (refer to the corresponding
'Hardware Manual'
to know the connector number)
X
3) Motor connection (refer to the corresponding
'Hardware Manual'
to know the connector number)
X
4) Power supply connection (refer to the corresponding
'Hardware Manual'
to know the connector number)
5) Motor protection (refer to the corresponding
'Hardware Manual'
to know the connector number)
X
6) Customer I/O (refer to the corresponding
'Hardware Manual'
to know the connector number)
X
ENCODER
MOTOR
Mains
220 V / 50-60 Hz
(Line & Neutral)
PC with
ETEL Tools
software installed
Power input
Auxiliary input
EBL 2 communication
P E
Always connect the
Protective Earth!