Chapter 6
Troubleshooting & Repairs
6-2
9009
Left Bin Door open
Safety breach!
RVM not operational
Close all Doors!
Left Bin Door is open.
Make sure that all doors are closed. If the
doors are closed, check the Diagnostic Pro-
gram (Main / Safety Loop) to see what is
causing this error.
9011
Right Bin Door open
Safety breach!
RVM not operational
Close all Doors!
Right Bin Door is open.
Make sure that all doors are closed. If the
doors are closed, check the Diagnostic Pro-
gram (Main / Safety Loop) to see what is
causing this error.
9014
Emergency cutout!
RVM not operational!
MC
1 triggered an emergency
shutoff.
9015
24
V
Power Fail
There is a problem with the
24
V
150
W
power supply in the
RVM
Controller Box.
9016
Breaker Compactor1 triggered
RVM not operational
Contact Envipco Support
The Variable Speed Drive for
Compactor 1 went into over-
load and shut down the
AC
compactor power.
If this error persists, there may be a problem
with the compactor or the
AC
motor.
9017
Breaker Compactor2 triggered
RVM not operational
Contact Envipco Support
The Variable Speed Drive for
Compactor 2 went into over-
load and shut down the
AC
compactor power.
If this error persists, there may be a problem
with the compactor or the
AC
motor.
9018
Compactor 1 jammed
RVM not operational
Contact Envipco Support
The
RPM
sensor on compactor
1 detected that the compactor
stalled. It is probably a jam.
Clear the compactor jam.
9019
Compactor 2 jammed
RVM not operational
Contact Envipco Support
The
RPM
sensor on compactor
2 detected that the compactor
stalled. It is probably a jam.
Clear the compactor jam.
9022
No Printer Client
RVM not operational
Contact Envipco Support
The Printer Process is not run-
ning on the
PC
board.
Check harnesses and connections. If that
fails, replace the
RVM
controller.
9023
No Display Client
RVM not operational
Contact Envipco Support
The Display Process is not run-
ning on the
PC
board.
Check harnesses and connections. If that
fails, replace the
RVM
controller.
9024
Hardware Init
-> Emergency cutout
RVM not operational
Contact Envipco Support
MC
1 triggered the safety inter-
lock during hardware initializa-
tion.
9025
Initialization failed
Make sure Sorter and Infeed are
free
RVM not operational
Contact Envipco Support
MC
5 initialization could not
complete for some reason.
Either the Sorting Cylinder or
In-Feed is jammed.
Clear any jams in the In-Feed or Sorting Cyl-
inder.
TABLE 6-1.
ULTRA Error Messages
Error# Error Message
Cause
Troubleshooting
Summary of Contents for U48DFF
Page 1: ...ULTRA Series Service Manual May 6 2014...
Page 2: ......
Page 18: ...Chapter 2 Specifications 2 2 FIGURE 2 2 ULTRA 48 Configuration...
Page 40: ...Chapter 3 Hardware Components 3 18 FIGURE 3 17 MC1 Board Layout FIGURE 3 18 MC5 Board Layout...
Page 41: ...3 19 RVM Controller Box FIGURE 3 19 MD5 Board Layout...
Page 52: ...Chapter 4 RVM Software 4 6 FIGURE 4 6 Service Mode Time Out Screen...
Page 68: ...Chapter 4 RVM Software 4 22 FIGURE 4 18 Software Processes Overview...
Page 69: ...4 23 Software Theory of Operation FIGURE 4 19 Circuit Board Locations...