Chapter 6
Troubleshooting & Repairs
6-10
3.
Screw the nuts back on.
6.5.3. Chain Replacement
If you need to replace a chain on a compactor or the Sorting Cylinder, follow these steps:
1.
Remove the chain cover, and position the chain so that the master link is in posi-
tion on the upper chain sprocket.
2.
Remove the master link from the chain.
3.
Remove the chain from the sprocket.
4.
Place the replacement chain on a sprocket in the same position.
5.
Install the master link, making sure that you place the clip in the proper position
according to the chain’s direction of rotation. See Figure 6-5.
FIGURE 6-5.
Master Link Clip Placement
6.5.4. Sensor Replacement
Certain sensors need to be configured when you install them into the
ULTRA
. Refer to the following sec-
tions when you replace sensors.
6.5.4.1. Wenglor Clear Material Sensor (K1R87NCT2)
The Wenglor clear material sensor is factory set for
NC
(normally closed) operation. It must be
set for
NO
(normally open) to operate in the Sensor Tunnel. When configured for
NO
opera-
tion, the indicator light goes off when blocked. To set the sensor for
NO
operation:
1.
Install the new sensor in the Sensor Tunnel.
2.
Align the sensor to the center of the retro-reflector.
Summary of Contents for U48DFF
Page 1: ...ULTRA Series Service Manual May 6 2014...
Page 2: ......
Page 18: ...Chapter 2 Specifications 2 2 FIGURE 2 2 ULTRA 48 Configuration...
Page 40: ...Chapter 3 Hardware Components 3 18 FIGURE 3 17 MC1 Board Layout FIGURE 3 18 MC5 Board Layout...
Page 41: ...3 19 RVM Controller Box FIGURE 3 19 MD5 Board Layout...
Page 52: ...Chapter 4 RVM Software 4 6 FIGURE 4 6 Service Mode Time Out Screen...
Page 68: ...Chapter 4 RVM Software 4 22 FIGURE 4 18 Software Processes Overview...
Page 69: ...4 23 Software Theory of Operation FIGURE 4 19 Circuit Board Locations...