Chapter 3
Hardware Components
3-22
amount of time, the
VFD
shuts down power to the compactor motor. This functionality replaces the old
mechanical motor protectors. It also soft-starts the compactor motor: it starts with a 0.5 second acceler-
ation, which prolongs the life of the compactor motor.
FIGURE 3-22.
Variable Frequency Drive
The
VFD
’s status display lists messages that may help troubleshoot compactor stalls. For more informa-
tion, See Section 6.3 “VFD Status Messages” on page 6-5.
3.8.3. Compactor 230V Three-Phase Connector
This is the output for the 230
V
three-phase power. The harness that provides power to the compactor
motor plugs into this connector.
3.8.4. 208-240V Single-Phase AC Power Output
This power output goes to the
RVM
Controller Box.
3.8.5. Safety Loop Override
This key switch overrides the door interlock, so that you may run the compactor with the front or rear
cabinet door open. When you are done with service, remove the key from this switch. If untrained peo-
ple have access to this override, they may be seriously injured by moving parts.
Status Display
Summary of Contents for U48DFF
Page 1: ...ULTRA Series Service Manual May 6 2014...
Page 2: ......
Page 18: ...Chapter 2 Specifications 2 2 FIGURE 2 2 ULTRA 48 Configuration...
Page 40: ...Chapter 3 Hardware Components 3 18 FIGURE 3 17 MC1 Board Layout FIGURE 3 18 MC5 Board Layout...
Page 41: ...3 19 RVM Controller Box FIGURE 3 19 MD5 Board Layout...
Page 52: ...Chapter 4 RVM Software 4 6 FIGURE 4 6 Service Mode Time Out Screen...
Page 68: ...Chapter 4 RVM Software 4 22 FIGURE 4 18 Software Processes Overview...
Page 69: ...4 23 Software Theory of Operation FIGURE 4 19 Circuit Board Locations...