6-5
VFD Status Messages
6.3. VFD Status Messages
The Variable Speed Drive (
VFD
) in the
AC
Motor Control Box has a status display that may help you
diagnose electrical problems on the
ULTRA
. The following is a list of useful status codes and their mean-
ings:
•
(Stop) - The drive is healthy and in a stopped condition. The motor is not
energized. No enable signal is present to start the drive.
•
.
(I.t-trp) - Motor thermal overload protection trip. The
VFD
shut down
the
AC
motor in order to protect it from thermal overload. Check the compactor
9708
Feed Ctrl Error
Light Sensor 5
Contact Envipco Support
Retro-reflector materials sen-
sor failure.
Clean sensor lens and reflector. Calibrate sen-
sor. Test the sensor with the Diagnostic Pro-
gram (Ultra-48 / Sensors).
9709
Feed Ctrl Error
Receipt Button
Contact Envipco Support
The receipt button has failed.
It may be stuck.
Check if the button is jammed.
9710
Feed Ctrl Error
Light Curtain
Contact Envipco Support
The Light Curtain is errone-
ously reporting that it is
blocked.
Check Light Curtain harnesses, especially the
ribbon cable that connects the two sides of
the light curtain (across the Sensor Tunnel).
Test it with the Diagnostic Program (Ultra-
48 / Sensors)
9711
Feed Ctrl Error
PET Sensor 1
Contact Envipco Support
P
ET
sensor 1 failed.
Clean the
PET
sensor emitter and receiver.
Calibrate it. Test it with the Diagnostic Pro-
gram (Ultra-48 / Sensors)
9712
Feed Ctrl Error
PET Sensor 2
Contact Envipco Support
P
ET
sensor 2 failed.
Clean the
PET
sensor emitter and receiver.
Calibrate the sensor. Test it with the Diag-
nostic Program (Ultra-48 / Sensors)
9713
Feed Ctrl Error
ALU Sensor
Contact Envipco Support
The aluminum sensor failed.
Test it with the Diagnostic Program (Ultra-
48 / Sensors)
9714
Feed Ctrl Error
Steel Sensor
Contact Envipco Support
The steel sensor failed.
Test it with the Diagnostic Program (Ultra-
48 / Sensors)
9715
Feed Ctrl Error
I2C Failure
Contact Envipco Support
There is a problem with the
connection between
MC
5 and
MD
5, or
MD
5 is not receiving
enough power for the motor
actuators (24
V
).
Check harnesses to
MC
5/
MD
5. Replace
boards if necessary.
9780
Feed Ctrl Error
Recovery unsuccessful
Call Staff
The
RVM
attempted to clear a
jam but was unsuccessful.
Clear the jam.
TABLE 6-1.
ULTRA Error Messages
Error# Error Message
Cause
Troubleshooting
Summary of Contents for U48DFF
Page 1: ...ULTRA Series Service Manual May 6 2014...
Page 2: ......
Page 18: ...Chapter 2 Specifications 2 2 FIGURE 2 2 ULTRA 48 Configuration...
Page 40: ...Chapter 3 Hardware Components 3 18 FIGURE 3 17 MC1 Board Layout FIGURE 3 18 MC5 Board Layout...
Page 41: ...3 19 RVM Controller Box FIGURE 3 19 MD5 Board Layout...
Page 52: ...Chapter 4 RVM Software 4 6 FIGURE 4 6 Service Mode Time Out Screen...
Page 68: ...Chapter 4 RVM Software 4 22 FIGURE 4 18 Software Processes Overview...
Page 69: ...4 23 Software Theory of Operation FIGURE 4 19 Circuit Board Locations...