3-17
RVM Controller Box
FIGURE 3-16.
PC Board Layout
3.7.2.2. Hard Drive
The hard drive is connected to the
PC
board, and stores all of the
RVM
’s data, including the bar
code table and counts, the
RVM
software, and
RVM
configuration.
3.7.2.3. Hardware Controller Boards
These custom boards control the motors in the
ULTRA
. There are three of these boards:
MC
1,
MC
5, and
MD
5. For a detailed discussion of how these boards work in concert with the
RVM
software, See Section 4.7 “Software Theory of Operation” on page 4-21.
•
MC1 Board - controls the safety interlock and the compactor. See Figure 3-17 for
the layout.
•
MC
5 &
MD
5 Boards - These two boards work together to control the In-Feed,
Sorting Cylinder, Rear Conveyor, and receipt button. M
C
5 also acts as an uninter-
ruptible power supply (
UPS
) controller to prevent data loss. See Section 3.7.1.1
“Battery Backup Feature” on page 3-14 for details. See Figure 3-18 and Figure 3-
19 for the layouts of these boards.
Summary of Contents for U48DFF
Page 1: ...ULTRA Series Service Manual May 6 2014...
Page 2: ......
Page 18: ...Chapter 2 Specifications 2 2 FIGURE 2 2 ULTRA 48 Configuration...
Page 40: ...Chapter 3 Hardware Components 3 18 FIGURE 3 17 MC1 Board Layout FIGURE 3 18 MC5 Board Layout...
Page 41: ...3 19 RVM Controller Box FIGURE 3 19 MD5 Board Layout...
Page 52: ...Chapter 4 RVM Software 4 6 FIGURE 4 6 Service Mode Time Out Screen...
Page 68: ...Chapter 4 RVM Software 4 22 FIGURE 4 18 Software Processes Overview...
Page 69: ...4 23 Software Theory of Operation FIGURE 4 19 Circuit Board Locations...