- 104 -
Chapter 5. Parameters
5.2 Description of basic parameters
- The parameters valid during POWER ON is displayed as ‘POWER’, and the parameter valid
during a RESET indicated as ‘RESET’.
- The setting value of [ ] is a setting value in a teach pendant.
P01
Types of controllers
Range
MCU-XL, XP2 , XA2
Unit
POWER
Definition
MCU-XP2: Pulse output type MCU [2]
MCU-XA2: Analog output type MCU [1]
MCU-XL: I/O control type MCU [0]
(Note) Do not change the value set during shipment from our company. If the
value is changed, then a window to confirm your password appears during
storage. If a wrong value is entered, then the controller works abnormally.
P02
Types of pulse outputs
Range
CW/CCW, Pulse/Direction
Unit
POWER
Definition
This is a parameter valid for MCU-XP2.
CW/CCW: The direction is directed by separate pulse trains. [0]
Pulse/Direction: The direction is directed by a direction signal. [1]
Description
The output type of a position command pulse train signal(PPA, PPB) is set by
MCU-XP2.
The forward rotation and reverse rotation pulse trains are generated when
setting CW/CCW.
The direction and pulse trains are generated when setting a Pulse/Direction.
(Note) Set it in the same way as the input pulse type of a position motor
drive. If a wrong value is input, the axis moves only in one direction.
PPA output
PPB output
Forward rotation
Reverse rotation
PPA output
PPB output
Forward rotation
Reverse rotation
Summary of Contents for MCU 2 Axis
Page 1: ...User s Manual 2 AXES...