- 152 -
Chapter 8. Alarm
Chapter 8. Alarm
Table 8.1 Alarm list
Division
No.
Message
Content and countermeasure
Information
2
PLC programs have been normally
compiled.
3
MC programs are under way, so their
compilation is impossible.
MC programs are under way in an automatic mode, so
the compilation of a PLC program is impossible.
Axis
100
SERVO NOT READY
The READY signals are not entered from the servo
driver.
101
FOLLOWING ERROR
The difference between the axis command position
and the machine position exceeds the range of
parameter P28(Following error).
102
+ SOFT LIMIT
The axis entered the prohibited area of a stored
stroke limit while the axis moves to the +
direction.
103
- SOFT LIMIT
The axis entered the prohibited area of a stored
stroke limit while the axis moves to the -
direction.
104
Forward direction LIMIT
The limit has been reached by the + direction
limit(input contact X0.0, X0.2) switch of the axis.
105
Reverse direction LIMIT
The limit has been reached by the - direction
limit(input contact X0.1, X0.3) switch of the axis.
MC
200
Invalid string
A command or letter violating syntax took place
during program execution.
201
No selected run programs
A program to be executed in an automatic operation
mode is not selected, or the selected program
doesn’t exist.
202
SOFT LIMIT
Invasion into a prohibited area of STORED STROKE
LIMIT before movement of an axis has been detected.
203
No label to jump
A label cannot be found when seeking an allotted
label by a GOTO, IN0, IN1, IF statement.
204
Out of POINT P TABLE range
The point setting has exceeded a range 0~99.
205
Out of Velocity F TABLE range
The velocity setting has exceeded a range 0~9.
206
Out of DWELL D TABLE range
The dwell setting has exceeded a range 0~9.
207
Too big dwell time
The DWL command value has exceeded a range
(1,000,000=1000 sec).
208
No designated contact at the IN, OUT
command
The designated contact was omitted in the IN0, IN1,
OUT0, OUT1 command.
209
No ‘.’ at the designated contact of
the IN, OUT command
There is no ‘.’ at the designated contact of the
IN0, IN1, OUT0, OUT1 command.
210
Over-range of the designated contact
at the IN, OUT command
The designated contact in an IN0, IN1, OUT0, OUT1
command has exceeded a range((0~59).(0~F))
211
No END
No END was commanded in a program under execution.
212
Over-multiplicity in the operational
expression
Multiplicity by (,), etc. in a MACRO operational
expression exceeded 5.
213
Unsuitable parenthesis
The number of (,) in a MACRO operational expression
is improper.
214
There cannot be a letter after =.
A letter unusable after = in a MACRO operational
expression was commanded.
215
There cannot be a letter after (.
A letter unusable after (was commanded in a MACRO
operational expression.
Summary of Contents for MCU 2 Axis