- 160 -
Chapter 9. Standard Input/ Output Signal
JOVE[M97.9] JOT[M97.F] JOV8[97.7] JOV4[M97.6] JOV2[M97.5] JOV1[M97.4]
X axis
Y axis
1
1
0
0
0
0
L60
L80
1
1
0
0
0
1
L61
L81
1
1
0
0
1
0
L62
L82
1
1
0
0
1
1
L63
L83
1
1
0
1
0
0
L64
L84
1
1
0
1
0
1
L65
L85
1
1
0
1
1
0
L66
L86
1
1
0
1
1
1
L67
L87
1
1
1
0
0
0
L68
L88
1
1
1
0
0
1
L69
L89
1
1
1
0
1
0
L70
L90
1
1
1
0
1
1
L71
L91
1
1
1
1
0
0
L72
L92
1
1
1
1
0
1
L73
L93
1
1
1
1
1
0
L74
L94
1
1
1
1
1
1
L75
L95
0
X
X
X
X
X
100%
23) MPG axis selection signal(in) MXY[
M97.A], *1[M97.B], *10[M97.C], *100[M97.D]
If the input signal of MXY is closed(1) in a MPG mode, then the Y axis in a MPG mode is
selected, and if it is opened(0), then the X axis is selected.
*100[M97.D]
*10[M97.C]
*1[M97.B]
Magnification
0
0
1
Move 1
μ
m per pulse
0
1
0
Move 10
μ
m per pulse
1
0
0
Move 100
μ
m per pulse
1
0
1
Move to a designated distance at L96 per pulse
1
1
0
Move to a designated distance at L97 per pulse
1
1
1
Move to a designated distance at L98 per pulse
* If the X axis gain of
basic
parameter P72(MPG gain) is set to more than 1000, then a
respective MPG can be used at each axis.
This function is applied to only the pulse motor(MCU-XP2).
24) Emergency Stop signal(in) ESP[ [
M80.0]
Emergency for input signal ESP can be inputted to a controller as open(0)
Æ
close(1), and it
is reset when the signal is open(0).
25) Servo OFF signal(in) Sof1[
M94.C],Sof2[M94.D]
The servo off for input signal SOF1, SOF2 can be turned OFF to open(0)
Æ
close(1), and if
the signal is open(0), then the servo is turned ON.
26) DWL input signal(in) by external encoders DWL [
M80.5]
If the “
basic
parameter P62 encoder accumulated dwell”(accumulation) or “
basic
parameter
P63 Encoder Dwell(M80.5) during dwell”(simple) are ‘Enable’, and if the input signal DWL
is closed(1), then it is reversed based on the set accumulation or simple.