- 122 -
Chapter 6. Connection
6.4 MCU-L
1) I/O Connector
- Counter Connector: HDBB-25P/HIROSE (P: Power, I: Input, O: Output)
Note)
a) The input contact of this product can be entered from 2 types of NPN and PNP, so 2 types
of sensors such as NPN and PNP can be used for an input contact.
b) For the extended I/O No.1, the input contact(IN0~IN11) is allotted as X3.4~X3.F and the
output contact(OUT0~OUT9) as Y1.E~Y2.7, and for the extended I/O No.2, the input
contact(IN0~IN11) is allotted as X5.4~X5.F and the output contact(OUT0~OUT9) as Y3.E~Y4.7.
Pin arrangement
Pin No. I/O
Signal name
Content
1
I
INCOM0
Input contact Common 0(IN0~IN5)
14
I
IN0
Input contact 0
2
I
IN1
Input contact 1
15
I
IN2
Input contact 2
3
I
IN3
Input contact 3
16
I
IN4
Input contact 4
4
I
IN5
Input contact 5
17
I
INCOM1
Input contact Common 1(IN6~IN11)
5
I
IN6
Input contact 6
18
I
IN7
Input contact 7
6
I
IN8
Input contact 8
19
I
IN9
Input contact 9
7
I
IN10
Input contact 10
20
I
IN11
Input contact 11
8
O
OUT0
Output contact 0
21
O
OUT1
Output contact 1
9
O
OUT2
Output contact 2
22
O
OUT3
Output contact 3
10
O
OUT4
Output contact 4
23
O
OUT5
Output contact 5
11
O
OUT6
Output contact 6
24
O
OUT7
Output contact 7
12
O
OUT8
Output contact 8
25
O
OUT9
Output contact 9
13
I
OUTCOM
Output contact Common(OUT0~9)