- 83 -
Chapter 4. PLC Program
6)
JOGX-
(1) Definition
An X axis -direction manual feed(JOG) application command executes manual feed in the -
direction, and outputs a state during execution of manual feed by a start command.
(2) Sequence and timing chart
LOAD X0.0
JOGX-
OUT Y0.0
X0.0
JOGX-
REQ
OUT
X0.0
Y0.0
Y0.0
JOGX- START
Summary of Contents for MCU 2 Axis
Page 1: ...User s Manual 2 AXES...