- 156 -
Chapter 9. Standard Input/ Output Signal
9.2 MC input signal(PLC
Æ
MC)
Table 9.2 MC input signal list
ADD
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
0
M80
A2-
A2+
A1-
A1+
ORG
STP
JOG
AUT
SGL
MPG
DWL
SP
ST
ERS
ESP
M81
Pl1F
Pl1E
Pl1D
Pl1C
Pl1B
Pl1A
Pl19
Pl18
Pl17
Pl16
Pl15
Pl14
Pl13
Pl12
Pl11
Pl10
M82
Ph1F
Ph1E
Ph1D
Ph1C
Ph1B
Ph1A
Ph19
Ph18
Ph17
Ph16
Ph15
Ph14
Ph13
Ph12
Ph11
Ph10
M83
Pl2F
Pl2E
Pl2D
Pl2C
Pl2B
Pl2A
Pl29
Pl28
Pl27
Pl26
Pl25
Pl24
Pl23
Pl22
Pl21
Pl20
M84
Ph2F
Ph2E
Ph2D
Ph2C
Ph2B
Ph2A
Ph29
Ph28
Ph27
Ph26
Ph25
Ph24
Ph23
Ph22
Ph21
Ph20
M85
FlF
FlE
FlD
FlC
FlB
FlA
Fl9
Fl8
Fl7
Fl6
Fl5
Fl4
Fl3
Fl2
Fl1
Fl0
M86
FhF
FhE
FhD
FhC
FhB
FhA
Fh9
Fh8
Fh7
Fh6
Fh5
Fh4
Fh3
Fh2
Fh1
Fh0
M87
S2
S1
I2
I1
DT2
DT1
DT0
DE
Dn7
Dn6
Dn5
Dn4
Dn3
Dn2
Dn1
Dn0
M88
Dl1F
Dl1E
Dl1D
Dl1C
Dl1B
Dl1A
Dl19
Dl18
Dl17
Dl16
Dl15
Dl14
Dl13
Dl12
Dl11
Dl10
M89
Dh1F
Dh1E
Dh1D
Dh1C
Dh1B
Dh1A
Dh19
Dh18
Dh17
Dh16
Dh15
Dh14
Dh13
Dh12
Dh11
Dh10
M90
Dl2F
Dl2E
Dl2D
Dl2C
Dl2B
Dl2A
Dl29
Dl28
Dl27
Dl26
Dl25
Dl24
Dl23
Dl22
Dl21
Dl20
M91
Dh2F
Dh2E
Dh2D
Dh2C
Dh2B
Dh2A
Dh29
Dh28
Dh27
Dh26
Dh25
Dh24
Dh23
Dh22
Dh21
Dh20
M92
AcF
AcE
AcD
AcC
AcB
AcA
Ac9
Ac8
Ac7
Ac6
Ac5
Ac4
Ac3
Ac2
Ac1
Ac0
M93
DcF
DcE
DcD
DcC
DcB
DcD
Dc9
Dc8
Dc7
Dc6
Dc5
Dc4
Dc3
Dc2
Dc1
Dc0
M94
ZS2
ZS1
Sof2
Sof1
T1
T0
FwE
DrE
DcE
AcE
M95
RlF
RlE
RlD
RlC
RlB
RlA
Rl9
Rl8
Rl7
Rl6
Rl5
Rl4
Rl3
Rl2
Rl1
Rl0
M96
RhF
RhE
RhD
RhC
RhB
RhA
Rh9
Rh8
Rh7
Rh6
Rh5
Rh4
Rh3
Rh2
Rh1
Rh0
M97
JOT
Mra
*100
*10
*1
MXY
JOVE
OVE
JOV8
JOV4
JOV2
JOV1
OV8
OV4
OV2
OV1
M98
M99
1)
External RESET signal(in) ERS
[
M80.1
]
The open(0)
Æ
close(1) of input signal ERS can reset a controller, and the reset output
signal RST[
M50.2] is turned ON.
2)
Automatic operation, STEP operation start signal(in) ST
[
M80.2
]
This is an effective signal only in an AUTO[
M50.8], STEP[M50.A] mode.
The open(0)
Æ
close(1) of input signal ST in an auto mode gets the controller to start
automatic operation, execute a machining program, and turn ON the signal STL[
M50.4] when
starting automatic operation.
The open(0)
Æ
close(1) of input signal ST in a step mode gets the controller to move a set
distance.
(For a STEP MODE, see the M81, M82, M83, M84, M85, M86, M87.C, M87.D, M87.E, M87.F, M94.6, M94.7, M95,
M96)
However, the following cases are ignored.
- When other modes than AUTO are selected
- When the controller is in an alarm state(The output signal AL
[
M50.3
]is ON)
- During a RESET(The output signal RST
[
M50.2
] is ON)
- During automatic operation(The output signal STL
[
M50.4
] is ON)
In the following cases, stop automatic operation and then turn OFF the output signal
STL[
M50.4]while starting automatic operation.
- When all execution has been completed
.
- When the input signal SP[
M80.3] was changed to open(0)
Æ
close(1)
- When a RESET was commanded
- When an ALARM happens
- When the mode was changed
.