J1.OK 3.2 mA DC (or equal) interposing relay will be mounted where the
contact wires terminate in the control/relay room.
4. Install cover and secure with captive washer, cover lock, and screw.
2.3
Electrical installation with remote electronics
All wiring must conform to local and national codes.
WARNING
Electrical shock
Disconnect and lock out power before connecting the unit to the power supply.
WARNING
Failure to install covers and ground leads could lead to serious injury or death.
Install all protective equipment covers and safety ground leads after installation.
WARNING
To meet the Safety Requirements of IEC 1010 (EC requirement) and to ensure safe
operation of this equipment, connect to the main electrical power supply through a
circuit breaker (minimum 10 A) which will disconnect all current-carrying conductors
during a fault situation.
This circuit breaker should also include a mechanically operated isolating switch.
If there is no switch, locate another external means of disconnecting the supply from
the equipment close by.
Circuit breakers or switches must comply with a recognized standard, such as IEC 947.
WARNING
The instrument is heavy.
Use proper lifting and carrying procedures to avoid personal injury.
WARNING
To maintain explosion-proof protection, all cable entry devices and blanking elements for
unused apertures must be certified flameproof and suitable for the conditions of use; they
must also be properly installed.
Note
To maintain CE compliance, ensure a good connection exists between the mounting
flange bolts and earth.
Install
Reference Manual
October 2019
00809-0100-4340
58
Emerson.com/Rosemount
Summary of Contents for Rosemount Oxymitter 4000
Page 4: ...4 ...
Page 8: ...Contents Reference Manual October 2019 00809 0100 4340 viii Emerson com Rosemount ...
Page 110: ...HART AMS Reference Manual October 2019 00809 0100 4340 110 Emerson com Rosemount ...
Page 114: ...HART AMS Reference Manual October 2019 00809 0100 4340 114 Emerson com Rosemount ...
Page 184: ...Optional accessories Reference Manual October 2019 00809 0100 4340 184 Emerson com Rosemount ...