3
6
3
5
3
7
3
8
3
9
4
0
4
1
4
2
4
3
4
4
4
5
4
6
4
7
4
8
4
9
5
0
3
1
3
2
3
3
3
4
5
1
5
2
5
3
5
4
5
5
5
6
5
7
5
8
ANALOGUE OUTPUT
TERMINALS
F
1
F
2
E
MAINS INPUT
TERMINALS
MAINS
FILTER
UNIT
4
2,5C
TO STATUS
RELAYS
3
2,3C
TO ANALOGUE
MODULES
5
2,5E
TO DIN
RAIL
TERMINALS
MAIN EARTH
CONNECTION
1
2
3
4
E
E
1
6
1
5
1
7
1
8
1
9
2
0
2
1
2
2
2
3
2
4
2
5
2
6
2
7
2
8
2
9
3
0
DIGITAL OUTPUT
TERMINALS
1
2,5E
TO DIGITAL
MODULES
1
4
1
3
1
2
1
1
STATUS OUTPUT
TERMINALS
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
1 2
1
SYSTEM SUPPLY (L)
USER CONNECTIONS
2
3
4
2
5
6
7
8
15
16
17
18
19
20
21
22
23
24
25
26
TERMINAL
FUNCTION
SYSTEM SUPPLY (N)
DGITAL OUTPUT 1
DGITAL OUTPUT 2
DGITAL OUTPUT 3
DGITAL OUTPUT 4
DGITAL OUTPUT 5
DGITAL OUTPUT 6
ANALOGUE OUTPUT 1
ANALOGUE OUTPUT 2
ANALOGUE OUTPUT 3
ANALOGUE OUTPUT 4
ANALOGUE OUTPUT 5
ANALOGUE OUTPUT 6
ANALOGUE OUTPUT 7
ANALOGUE OUTPUT 8
9
10
11
12
13
14
DGITAL OUTPUT 7
DGITAL OUTPUT 8
DGITAL OUTPUT 9
DGITAL OUTPUT 10
DGITAL OUTPUT 11
DGITAL OUTPUT 12
STATUS OUTPUT 1 (Check Function)
STATUS OUTPUT 2 (Maintenance reqd.)
STATUS OUTPUT 3 (Out of Sepecification)
STATUS OUTPUT 4 (Failed)
+
+
+
+
+
+
+
+
-
-
-
-
-
-
-
-
C
NO
NO
C
NO
C
NO
C
NO
C
NO
C
NO
C
NO
C
NO
C
NO
C
NO
C
NO
C
C
NO
C
NO
C
NO
C
NO
1 3 5 7 S
2 4 6 8
ETHERNET
INTERFACE
MODULE
2
2,5C
TO MOXA
ETHERNET
SOCKET
(OPTIONAL)
TERMINAL
DESIGNATION
COLOUR CODING
Orange/White
2
Tx−
Orange
3
Rx+
Green/White
4
Not Used
Blue
5
Not Used
Blue/White
6
Rx−
Green
7
Not Used
Brown/White
8
Not Used
Brown
NOTES ;−
1. To Connect to ethernet signal using muticore cable tails connect the
cable as per the above table
2. To connect to ethernet network using an RJ45 connector unplug the
ethernet cable, marked
*,
that goes from the ethernet interafce module
to the Moxa moudle at the Moxa module end and plug in the extrenal
RJ45 netwrok to the Moxa port
*
Tx+
1
E
CERTIFICATION RELATED
DOCUMENT, UNAUTHORISED
ALTERATION, STRICTLY
NON PERMISSIBLE
B
A
2
1
3
4
5
6
7
8
C
D
E
B
A
C
D
E
A3
CASCADE TECHNOLOGIES LTD
GLENDEVON HOUSE-CASTLE BUSINESS PARK
STIRLING FK9 4TZ-UK
THIS DRAWING AND DATA CONTAINED WITHIN IT ARE THE SOLE
PROPERTY OF CASCADE TECHNOLOGIES LTD, PART OF EMERSON
PROCESS MANAGEMENT AND CANNOT BE COPIED, COMMUNICATED
OR REPLICATED PARTIALLY OR IN ITS ENTIRETY WITHOUT
EXPRESSED WRITTEN CONSENT BY CASCADE TECHNOLOGIES LTD.
GENERAL DRAWING PRACTICE TO ISO14617, PNEUMATIC SYMBOLS DRAWN
TO ISO1219-1, PIPING AND INSTRUMENTATION DIAGRAMS (P&ID) DRAWN TO
ISO 10628, WIRING DRAWN TO IEC61346 & ICS 19-2002, WHERE APPLICABLE,
CUSTOM SYMBOLS LISTED ON KEY PROVIDED, BLOCK DIAGRAMS CAN BE
INSERTED TO CLARIFY FUNCTIONALITY.
DO NOT SCALE
DO NOT ALTER
MANUALLY
DRAWING No:
DESCRIPTION:
REV.
DRAWN BY
CHECKED BY
ISSUE DATE
1
1,2A
BALLOON I.D. NO.
DRAWING SHEET LOC.
SHEET OF
DRAWING SHEET NO.
D
R
G
N
o
:
T
E
M
P
L
A
T
E
:
7
.3
.3
.0
0
0
0
1-
0
6
R
E
V
IS
IO
N
:
S
A
V
E
D
B
Y
:
W
-
2
00
0
-
0
0
3
8
B
jc
h
a
lm
e
rs
D
A
T
E
L
A
S
T
S
A
V
E
D
:1
9
-
O
ct
-
17
1
3
:5
6
CT5800 GAS ANALYZER
W-2000-0038
B
JMC
28/11/2016
5
1
??
Summary of Contents for Rosemount CT5800
Page 20: ...Contents Reference Manual September 2019 00809 0100 5800 xx Emerson com Rosemount ...
Page 34: ...Plan Reference Manual September 2019 00809 0100 5800 34 Emerson com Rosemount ...
Page 60: ...Startup procedure Reference Manual September 2019 00809 0100 5800 60 Emerson com Rosemount ...
Page 90: ...Gas calibration Reference Manual September 2019 00809 0100 5800 90 Emerson com Rosemount ...
Page 168: ...Shutdown procedure Reference Manual September 2019 00809 0100 5800 168 Emerson com Rosemount ...
Page 178: ...Theory of operation Reference Manual September 2019 00809 0100 5800 178 Emerson com Rosemount ...
Page 180: ...Spare parts list Reference Manual September 2019 00809 0100 5800 180 Emerson com Rosemount ...