Online Watch—Transient Archive Status
Figure 6-3:
Transient Archive Status fields
Table 6-2:
Field
Message
Description
Component
(variable)
Displays the machine component associated with the transient archive
group.
Archive Name
(variable)
Displays the name of the archive that was specified in Online
Configuration.
Range 1500_2985
indicates that the collection predicate is TRUE for
speeds between 1500 and 2985 RPM.
The number in
_0__
is reserved to ensure the filename is always unique.
05-30-2007
indicates the date the archive was created, in mm-dd-yyy
format.
10.17.07
indicates the time the archive was created, in hh.mm.ss format.
Archive Status
Pending
The system is waiting for post-trigger data to be collected, before
sending that data to the database.
Archiving
The system is sending a complete set of measurements to the online
server.
Complete
All measurements have been sent to the online server.
Archive Type
Pre parameters
The archive was initiated by a predicate.
Manual
The archive was initiated on-demand by a user.
Percent
Complete
00.00%–100.00%
Displays progress while the system sends measurements to the online
server.
6.5
Archive management
Archives are stored in folders in
C:\RBMnet\RBMsuite\CustData\
.
Computers have a finite amount of video display memory that may limit the amount of
graphic data viewed in an archive. To achieve efficient CSI 2600 system operation, an
analyst should regularly review extracted archives and keep only those of interest or only
the portions of interest in each archive. An analyst can extract smaller archives from large
ones using the program Vibration Analysis. To extract and view large amounts of
information from the CSI 2600, an analyst should sequentially extract individual archives of
1 - 2 hours of measurements.
Data collection and analysis
MHM-97453, Rev 1
69
Summary of Contents for Machinery Health Expert CSI 2600
Page 1: ...User Guide MHM 97453 Rev 1 April 2014 CSI 2600 Machinery Health Expert User Guide ...
Page 8: ...CSI 2600 back view Figure 2 2 Introduction to the CSI 2600 4 MHM 97453 Rev 1 ...
Page 12: ...Introduction to the CSI 2600 8 MHM 97453 Rev 1 ...
Page 26: ...Getting started 22 MHM 97453 Rev 1 ...
Page 64: ...Software configuration 60 MHM 97453 Rev 1 ...
Page 96: ...Data types 92 MHM 97453 Rev 1 ...
Page 100: ...D 2 Internal wiring diagram for the CSI 2600 ...
Page 106: ...Troubleshooting 102 MHM 97453 Rev 1 ...
Page 109: ...Index MHM 97453 Rev 1 105 ...