3.
Machine starts up and increases to a speed of 1800 RPM.
4.
Archive predicate is re-enabled.
5.
Archive predicate immediately changes to value of
TRUE
.
6.
No archive is created.
7.
Machine speed continues to rise and reaches a speed of 3000 RPM.
8.
Archive predicate changes to value of
FALSE
.
9.
Machine trips and speed drops below 2985 RPM.
10.
Archive predicate changes to value of
TRUE
.
11.
Archive is automatically created and sent to online server.
Disabling or re-enabling archive predicates only determine whether or not the CSI 2600
will send an archive to the online server. This does not stop the CSI 2600 from recording
measurements. In the above sequence, an analyst could extract a manual archive starting
at the time when the archive predicate was initially false and ending at the time that the
machine was at 3000 RPM.
6.8
Stop transient acquisition
An analyst can command the CSI 2600 to stop recording transient data.
Procedure
1.
In the Online Watch tree structure, right-click on the CSI 2600 and select
Stop
Transient Acquisition
.
A caution window appears.
2.
Click
Okay
to confirm.
In the Transient Status tab, Current Acquisition State displays the message
Transient
Acquisition has stopped
, and the CSI 2600 is no longer streaming data to the designated drive.
6.9
Remove an archive from the Transient Archive
Status tab
In the Transient Archive Status tab, right-click on the archive and select
Acknowledge
Transient Archive
.
Note
Removing archives does not delete archives from the online server; it only removes them from the
list in the Transient Archive Status tab.
Data collection and analysis
MHM-97453, Rev 1
71
Summary of Contents for Machinery Health Expert CSI 2600
Page 1: ...User Guide MHM 97453 Rev 1 April 2014 CSI 2600 Machinery Health Expert User Guide ...
Page 8: ...CSI 2600 back view Figure 2 2 Introduction to the CSI 2600 4 MHM 97453 Rev 1 ...
Page 12: ...Introduction to the CSI 2600 8 MHM 97453 Rev 1 ...
Page 26: ...Getting started 22 MHM 97453 Rev 1 ...
Page 64: ...Software configuration 60 MHM 97453 Rev 1 ...
Page 96: ...Data types 92 MHM 97453 Rev 1 ...
Page 100: ...D 2 Internal wiring diagram for the CSI 2600 ...
Page 106: ...Troubleshooting 102 MHM 97453 Rev 1 ...
Page 109: ...Index MHM 97453 Rev 1 105 ...