6.2
Verify or assign IP addresses to the database
The online database must be configured with the IP addresses of assigned monitoring
units.
Procedure
1.
Log in to AMS Machinery Manager and click on RBM Network Administration.
2.
In the RBMadmin window, double-click the server listed under the Online Server
panel.
3.
In the Online Server Setup window, the Active Units panel lists the IP addresses of
units available for the online server.
If the system is configured to store data in a database, a database will be displayed in
the Machinery Health Manager Database frame, the two
Edit
buttons will be inactive,
and the
Stop Data Collection
button will be inactive.
4.
If necessary, assign the IP address of a CSI 2600 to Active Units.
a. In the Online Server Setup window, click
Stop Data Collection
.
b. Beside the Active Units panel, click
Edit
.
c. In the Edit Online Server's Active Unit List window, type the IP address of a new
CSI 2600 in the New Unit field.
d. Click
Add New
.
The IP address appears in the Active Units panel.
e. Click
OK
.
The Edit Online Server's Active Unit List window will close.
f. In the Online Server Setup window, click
Start Data Collection
.
Once a CSI 2600 IP address is listed in RBM Network Administration, that address may be
used for any existing or future database built with the online server. This task does not
need to be performed each time a new database is built.
6.3
Database configuration: overview
Configuring a database is different for a CSI 2600 than for other online monitoring
applications. In most cases, the CSI 2600 is not connected directly to sensors. Rather, it is
connected through coax cable with BNC connectors to a panel of monitoring modules.
These modules are connected to field wiring. Therefore, when building a database, it is
important to have a diagram that shows what sensors are connected to which monitoring
modules. In addition, an analyst who builds a CSI 2600 database needs to know if the
monitoring modules perform any signal conditioning on the input signals before passing
them through to their output connectors.
Data collection and analysis
62
MHM-97453, Rev 1
Summary of Contents for Machinery Health Expert CSI 2600
Page 1: ...User Guide MHM 97453 Rev 1 April 2014 CSI 2600 Machinery Health Expert User Guide ...
Page 8: ...CSI 2600 back view Figure 2 2 Introduction to the CSI 2600 4 MHM 97453 Rev 1 ...
Page 12: ...Introduction to the CSI 2600 8 MHM 97453 Rev 1 ...
Page 26: ...Getting started 22 MHM 97453 Rev 1 ...
Page 64: ...Software configuration 60 MHM 97453 Rev 1 ...
Page 96: ...Data types 92 MHM 97453 Rev 1 ...
Page 100: ...D 2 Internal wiring diagram for the CSI 2600 ...
Page 106: ...Troubleshooting 102 MHM 97453 Rev 1 ...
Page 109: ...Index MHM 97453 Rev 1 105 ...