4.9.5
Install mounting studs
For use when installing A911 mounting stud or A0322 Quick-Connect base.
Procedure
1.
Using a plant-approved degreaser, remove any lubricating fluid used during the
tapping process.
2.
Using a plant-approved epoxy, rub a small amount of epoxy onto spot face.
3.
Using a 0.25 in. allen wrench, loosely screw a mounting base into the mounting
location.
4.
Using a torque wrench with a 0.25 in. hex bit, torque to 7-8 ft-lbs.
If the mounting base is not seated against the spot face after torquing, the tap was
not deep enough.
5.
If the sensor will not be mounted immediately, cover exposed quick-connect
threads to prevent contamination. Industrial tape is recommended.
A911 Quick-Connect
Figure 4-12:
4.9.6
Mount accelerometers
Prerequisites
Note
If you are not ready to pull cables, do not mount sensors on the machine. If it is necessary to mount a
sensor, the bundled cable must be secured to the machine and protected from damage.
Procedure
1.
Using a plant-approved cleaner/degreaser, remove any lubricating fluid used during
the tapping process and clean the mounting stud threads.
2.
Rub a small amount of semi-permanent thread locker onto the mounting location.
Hardware configuration: overview
MHM-97453, Rev 1
39
Summary of Contents for Machinery Health Expert CSI 2600
Page 1: ...User Guide MHM 97453 Rev 1 April 2014 CSI 2600 Machinery Health Expert User Guide ...
Page 8: ...CSI 2600 back view Figure 2 2 Introduction to the CSI 2600 4 MHM 97453 Rev 1 ...
Page 12: ...Introduction to the CSI 2600 8 MHM 97453 Rev 1 ...
Page 26: ...Getting started 22 MHM 97453 Rev 1 ...
Page 64: ...Software configuration 60 MHM 97453 Rev 1 ...
Page 96: ...Data types 92 MHM 97453 Rev 1 ...
Page 100: ...D 2 Internal wiring diagram for the CSI 2600 ...
Page 106: ...Troubleshooting 102 MHM 97453 Rev 1 ...
Page 109: ...Index MHM 97453 Rev 1 105 ...