Install the firmware on the FTP server
Prerequisites
You need the AMS Machinery Manager Software Installation DVD.
Procedure
1.
Log on to the computer that hosts the FTP Server for your CSI Machinery Health
Monitor.
2.
Insert the AMS Machinery Manager Software Installation DVD.
3.
Open the DVD in Windows Explorer and browse to
Install/Online Firmware
.
4.
Double-click
setup.exe
and continue through the installation.
Important
On Windows 7 and Windows Server 2008, right click
setup.exe
and select
Run as administrator
.
5.
Accept the license agreement.
6.
Select the type of installation.
•
Select Typical to install the firmware and tools.
•
Select Custom to choose to install either the firmware or the tools.
7.
Follow instructions presented by the installation program.
The online firmware is installed in
C:\Inetpub\ftproot\bin\
.
Postrequisites
Cycle the power on each CSI Machinery Health Monitor that uses this FTP server.
Reboot the CSI Machinery Health Monitor
Cycle power on the CSI Machinery Health Monitor and verify the system is in good status
after it boots.
Procedure
1.
Cycle the power on each CSI Machinery Health Monitor that needs to get the new
firmware update from the FTP server.
2.
Wait approximately 5 minutes for the system to complete the boot process.
3.
Verify the system is powered on and in good status.
Refer to the Installation Manual for your specific hardware model for more
information.
Check the firmware version in AMS Machinery Manager
1.
Log on to AMS Machinery Manager Client with the Administrator user account or a
user that has permission to use online technology.
Software configuration
50
MHM-97453, Rev 1
Summary of Contents for Machinery Health Expert CSI 2600
Page 1: ...User Guide MHM 97453 Rev 1 April 2014 CSI 2600 Machinery Health Expert User Guide ...
Page 8: ...CSI 2600 back view Figure 2 2 Introduction to the CSI 2600 4 MHM 97453 Rev 1 ...
Page 12: ...Introduction to the CSI 2600 8 MHM 97453 Rev 1 ...
Page 26: ...Getting started 22 MHM 97453 Rev 1 ...
Page 64: ...Software configuration 60 MHM 97453 Rev 1 ...
Page 96: ...Data types 92 MHM 97453 Rev 1 ...
Page 100: ...D 2 Internal wiring diagram for the CSI 2600 ...
Page 106: ...Troubleshooting 102 MHM 97453 Rev 1 ...
Page 109: ...Index MHM 97453 Rev 1 105 ...