CSI Machinery Health Monitor FTP configuration
Table 5-2:
Setting
Description
Site name
The FTP site name to display in IIS Manager. This is for your
reference.
Physical path
The path to the
bin
directory where the firmware will be installed on
the FTP server (do not include the
bin
directory).
C:\Inetpub\ftproot
, for
example.
Binding
Set
Binding
to
All Unassigned
or the IP address or a range of IP
addresses assigned to this computer. Do NOT enable virtual host
names.
Start FTP site
automatically
Allow the site to start automatically. Check
Start FTP site automatically
.
Security
Choose
Allow SSL
and do not select a certificate.
Authentication
Choose
Anonymous
if the CSI Machinery Health Monitor's
user (u)
and
password (pw)
boot parameters are set to anonymous.
Authorization
Choose
Anonymous users
if the CSI Machinery Health Monitor's
user (u)
and
password (pw)
boot parameters are set to anonymous.
Permissions
Read
The FTP site name appears in the
Connections
pane and the site is started.
Postrequisites
Install the firmware on this computer. You can store the firmware for different hardware
models on the same FTP server.
CSI Machinery Health Monitor FTP settings
Table 5-3:
Boot parameter
Definition
Default settings
host inet (h)
The IP address of the FTP server
192.168.0.1
user (u)
The username for the FTP account
anonymous
ftp password (pw)
The password for the FTP user
anonymous
5.6.1
CSI Machinery Health Monitor firmware update
Emerson Process Management periodically releases updates to firmware. When you
update your AMS Machinery Manager software, it is a good practice to update the
firmware if a new version is available. Refer to the Readme file (Readme.rtf) on the
Software Installation DVD for information about the current firmware version. These
instructions apply to the following CSI Machinery Health Monitor systems:
•
CSI 6500 Machinery Health Monitor
•
CSI 2600 Machinery Health Expert
•
CSI 4500 Machinery Health Monitor
Software configuration
MHM-97453, Rev 1
49
Summary of Contents for Machinery Health Expert CSI 2600
Page 1: ...User Guide MHM 97453 Rev 1 April 2014 CSI 2600 Machinery Health Expert User Guide ...
Page 8: ...CSI 2600 back view Figure 2 2 Introduction to the CSI 2600 4 MHM 97453 Rev 1 ...
Page 12: ...Introduction to the CSI 2600 8 MHM 97453 Rev 1 ...
Page 26: ...Getting started 22 MHM 97453 Rev 1 ...
Page 64: ...Software configuration 60 MHM 97453 Rev 1 ...
Page 96: ...Data types 92 MHM 97453 Rev 1 ...
Page 100: ...D 2 Internal wiring diagram for the CSI 2600 ...
Page 106: ...Troubleshooting 102 MHM 97453 Rev 1 ...
Page 109: ...Index MHM 97453 Rev 1 105 ...