C6.1.6/0117-1017/E
17
Parameter
Description
Factory settings /
Range
Recommended settings / Comments
G40
First weekly
holiday
SUN
= Sunday
0 =
SUN
; 1 =
MON
; 2 =
TUE
; 3 =
WED
;
4 =
THU
; 5 =
FRI
; 6 =
SAT
;
7 =
nu
= Not used
G41
Second weekly
holiday
SUN
= Sunday
0 =
SUN
; 1 =
MON
; 2 =
TUE
; 3 =
WED
;
4 =
THU
; 5 =
FRI
; 6 =
SAT
;
7 =
nu
= Not used
G42****
Fan operating
mode
0 =
cn
= Stopped
during defrost
0 =
cn
; 1 =
On
; 2 =
cy
; 3 =
Oy
G43
Fan stop
Temperature
0°C
-40°C to 110°C
G55
Fan delay after
defrost / drip time
1 minute
0 to 255 minutes
S05
Relay output 2
configuration
0 = Not used =
nu
6 = Defrost =
dEF
Table 13: Defrost parameters
* G17 parameter >> Three defrost modes are available:
▪
G17 = EL
→ Defrost through electrical heater
Compressor Off
▪
G17 = pulse
→ Pulse / natural defrost
Compressor Off
** G23 parameter >> Defrost interval mode:
▪
G23 = nu (0)
→ Defrost functionality not used
▪
G23 = in (1)
→ Defrost in intervals G18
▪
G23 = rtC (2)
→ Enables defrost for rtC (real time clock), allows timing of defrost cycles
with G28
– G41
*** G24 parameter >> Display during defrost:
▪
G24 = dEF (0)
→ Display shows "dEF" for defrost
▪
G24 = SET (1)
→ Display shows "G02" parameter value = Case temperature setpoint
▪
G24 = it (2)
→ Display shows display case temperature value
▪
G24 = rt (3)
→ Display will stay in standard operation
**** G42 parameter >> Evaporator fans function:
▪
G42 = cn (0)
→ Will switch On and Off with the compressor, Off during defrost
▪
G42 = On (1)
→ Fans On, even if the compressor is off, Off during defrost
o
After defrost, there is a timed fan delay allowing for drip time, set by means of the
"G55" parameter.
▪
G42 = cy (2)
→ Fans will switch On and Off with the compressor, On during defrost
▪
G42 = Oy (3)
→Fans will run continuously also during defrost
Manual defrost
Please check settings for evaporator fans. The XCM25D controller is able to control the evaporator
fan.
NOTE: For additional features please contact your local Application Engineering
representative.
2.10 XCM25D Electronic controller
– Programming
CAUTION
Low refrigerant charge! Compressor damage!
Never energize the
unit/controller without minimum refrigerant system charge. There is a risk of
malfunction of the controller in deep vacuum operation which can cause
compressor damage.
S
afet
y
inst
ru
ctio
n
s
P
ro
d
u
ct
d
es
cr
ipt
ion
Inst
all
atio
n
S
tar
ting
up
&
o
p
er
atio
n
Ma
int
enan
c
e &
repai
r
Cer
tif
ica
tion
&
a
p
p
ro
va
l
Dismant
ling
&
d
ispo
sa
l