40
Maintenance Procedures
Installation
IND100078-42
▼4: Remove the Top Stand Covers first as indicated. 4 screws
on both sides.
▼5: Remove the Bottom Stand Covers first as indicated. 6 screws
on both sides.
▼6: Identify which Actuator to replace. Unit must be raised
to highest level on the remaining Actuator. Each Actuator is
secured by 4 top screws on the top. Notice their location below
before removal.
▼7: Close-up of the 4 screws to remove. Once removed, simply use
your hands to pull down the inner cylinder to the bottom. Notice the
cable connection on top of it and unplug it also.
▼8: Finally, remove the last 4 screws (2 on each side) that holds the Actuator in place at its base as illustrated and remove/replace the
Actuator. Reverse this procedure to assemble everything back together again.