27
General Installation Recommendations
Installation
IND100210-31
Configuring Housing / Terminal Block connectors
Below is a brief illustration that might be useful during configuration and installation of such connectors. You will need
suitable pre-configured cable(s) and tools to configure the connector(s) and cable(s) that are present in your
installation environment. Below is a sample procedure for a 2-pin DC power connector. The procedure is the same for
other connectors of this type as listed in table above. Unit used as illustration below is for reference only.
FIG 5
FIG 1
FIG 4
FIG 6
FIG 2
FIG 3
Requires assembly. It is expected that the technician has experience in electronics and
assembling cables and connectors.
Warning:
Do not connect or disconnect cables/connectors to the unit’s connector while the unit is powered on. Failure to do so may result in
damaged electronics.
FIG 1:
Unscrew (from top) or make sure that the screw terminal is fully open, so you can secure the inserted cables
correctly to the loose housing connector (it may already be plugged into the unit as per factory installation).
FIG 2:
Strip carefully the insulation from the cable to expose the wire(s) inside.
FIG 3:
Ensure that the wire(s) is without any loose threads to ensure good connection.
FIG 4:
Insert cables* (from front) and screw / secure the cables by turning the screw on top of the housing to secure
the cables properly. Check that the cables are firmly in place and do not appear loose or fall out when pulling gently.
*Note: Required polarization verification (for instance -/+ for DC power input) should conform with the markings on
the connector area of the unit. Ignoring the markings on the unit or its add-on modules might damage the unit and/or
external equipment in which end, warranty will be void.
FIG 5:
Plug the housing into the appropriate connector area of the unit (glass should be facing down) and check again
that the cables secured conform with the markings on the connector area of the unit. Finalize the installation by
fastening the screws located in front on each side of the housing connector
(FIG 6).
Connector / Function
Recommended Cable Thickness
2-pin DC Power Input (Terminal Block 5.08)
Minimum 20 AWG - Maximum 18 AWG
4-pin CAN (Terminal Block 3.81)
Minimum 22 AWG - Maximum 20 AWG
5-pin NMEA COM (Terminal Block 3.81)
Minimum 22 AWG - Maximum 18 AWG
5-pin DIO (Terminal Block 3.81)
Minimum 22 AWG - Maximum 18 AWG
Summary of Contents for Hatteland X Series
Page 8: ...8 This page left intentionally blank...
Page 9: ...9 General...
Page 17: ...17 Installation...
Page 35: ...35 Maintenance...
Page 47: ...47 Operation...
Page 83: ...83 Operation Advanced DDC CI...
Page 87: ...87 Specifications...
Page 98: ...98 This page left intentionally blank...
Page 99: ...99 Technical Drawings...
Page 101: ...101 IND100132 281 Technical Drawings HD 55T22 MVD MA1 TxGx Cable Openings...
Page 111: ...111 Technical Drawings Accessories...
Page 116: ...116 This page left intentionally blank...
Page 117: ...117 Appendixes...
Page 131: ...131 Appendix IND100077 24 User Notes...
Page 133: ...133 Revision History Appendix IND100077 161...
Page 134: ...Hatteland Technology AS www hattelandtechnology com Enterprise no NO974533146...